NI LabVIEW 2013 MAC OS X32Eng LV2013苹果系统评估版
Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html
NI LabVIEW 2013 MAC OS X32Eng LV2013苹果系统评估版
百度网盘下载地址和NI官方下载地址:
注册登录视觉论坛账号,购买附件下载查看
LabVIEW 2013 Readme for OS XVersion 13.0.0June 2013This file contains late breaking news about LabVIEW 2013 for Linux and supersedes any information found in other documentation included in the distribution. Refer to ni.com/linux for the most recent information about Linux support at National Instruments.Refer to the LabVIEW Help located in the labview/help directory for more information about LabVIEW 2013.Refer to the labview/readme directory for readme files about LabVIEW add-ons, such as modules and toolkits.System Requirements
Installation Instructions
Known Issues
Additions to the LabVIEW Help
Bug Fixes
Important Information
System Requirements
OS XRun-Time EngineDevelopment Environment
ProcessorIntel-based processorIntel-based processor
RAM256 MB1 GB
Screen Resolution1024 x 768 Pixels1024 x 768 Pixels
Operating SystemOS X 10.5, 10.6, 10.7, or 10.8OS X 10.7 or 10.8
Disk Space656 MB - 1.2 GB1.2 GB for the complete installation (excluding drivers)
Temporary Files DirectoryN/ALabVIEW uses a directory for storing temporary files. National Instruments recommends that you have several megabytes of disk space available for this temporary directory.
NoteNational Instruments recommends that you use Firefox 3.0 or later or Safari 3.0.4 or later to view the LabVIEW Help.
Installation InstructionsDepending on whether you are installing LabVIEW for the first time or upgrading from a previous version, refer to one of the following documents for information about installing LabVIEW:
[*]LabVIEW Installation Guide—Includes information about installing LabVIEW, modules and toolkits, drivers, and hardware.
[*]LabVIEW Upgrade Notes—Includes information about protecting existing VIs and projects before you install a new version of LabVIEW, as well as upgrade and compatibility issues and a complete list of new features in LabVIEW 2013.
You can access the LabVIEW Installation Guide and the LabVIEW Upgrade Notes at ni.com as well as on the installation media.NoteIf you purchased this product with an NI Software Suite or NI Product Bundle, use the installation media that shipped with your purchase to install this product.Known IssuesYou can access the software and documentation known issues list online. Refer to the National Instruments website for an up-to-date list of known issues in LabVIEW 2013.Additions to the LabVIEW HelpThe following list contains additional changes to LabVIEW that are not included in the LabVIEW Help, the LabVIEW Upgrade Notes, or both:
[*]Because LabVIEW 2013 may apply different compiler optimizations on different machines, you may need to perform additional steps to guarantee that a built application contains the same binary contents when built on different machines. Refer to the National Instruments website for more information about reproducing builds in LabVIEW 2013.
[*]If you create a VI that overrides a property accessor VI in a parent LabVIEW class, you must provide the same name and folder path in the property definition folders for both the child and parent classes.
Bug FixesThe following items are the IDs and titles of a subset of issues fixed in LabVIEW 2013. This is not an exhaustive list of issues fixed in the current version of LabVIEW. If you have a CAR ID, you can search this list to validate the issue has been fixed.
IDLegacy IDFixed Issue
3960449UBP4LEWrite to Clipboard Method consumes 100% of CPU for several minutes
439314GPF7QYESave Report to File.vi copies images from Temp rather than moving them
91672477M7K00Large amounts of data in combo box can appear to hang LabVIEW
136939—Dragging an unsaved VI from one project to another, and then closing the original project without saving corrupts the VI
138552—Load VRML File.vi missing "error in" terminal
148149—Event Structure cases can incorrectly remap to other dynamic events
214989—Dropping a System OK button silently removes any existing key binding for the <Return> key
221251—Shared Variable values discarded after system restart
233963—Service Locator does not work when installed to a path containing stress characters
240362—Image in Header or Footer.vi created HTML-files with one additional unwanted '<' character
242214—LabVIEW does not marshal .NET objects, so you cannot make a LabVIEW .NET assembly with a usable .NET refnum in the connector pane
248755—Zoom, pan, and rotate sometimes cause 3D objects to move in 3D Scene Displays
253088—Programmatic tab view changes sometimes fail if front panel controls are being updated with property nodes
256978—Custom Font Setting tokens in LabVIEW.ini file are overwritten when you modify any other part of the INI file
279047—Coercing a cluster containing a cluster to a variant can cause the inner cluster to have its labels change
280941—DWarn: ProjectItem.cpp line 8914 sometimes thrown when using auto-populating folders
287984—lvanlys.dll fails to load on an 8 core processor
288741—Non-handled, registered dynamic events reset the Event structure timeout
294464—Connected PSP property returns error on Shared Variables that have write only access
300375—Scan From String returns error when using %y%m formatting with 2 digit years
301753—SMTP Email Send Message VI: Subject line with more than 45 connected characters causes error
303503—When a LVM file is read by the Read from Measurement File Express VI, the Y Unit attribute is ignored
306025—Changing the front properties of a front panel object affects all objects created after it
309897—Scan from String incorrectly parses a string containing SI notation
312458—Fatal Internal Error: "proptype.cpp" sometimes displayed when programmatically exiting LabVIEW
312533—Private member VIs of a library can be exported in .NET interop assemblies
315663—Files inside a NIER Report have the incorrect date
317314—LabVIEW "Terminal" based web services don't display more than 6 digits of precision
318263—Changing a type def text ring control to a constant causes the display format to change to floating point
319888—Using NaN in Y array of XY Graph causes line not to plot
321518—Nested source-only type-defined clusters may not propagate changes to calling VIs
322705—Find and Replace text sometimes does not find all instances of text
323078—Silver XY Graph's legend does not snap to upper-right corner of graph when control is set to fit to pane
325150—The tip strips for the Variant To/From Element nodes on the In Place Element structure are missing
330806—Incorrect time stamp plotted when using Express VIs
331293—Font changes to XY Graph affect non-selected controls
334314—Creating an Override VI for a child class that has a parent in a Packed Project Library gives error 1035
334661—Pane setting "Scale Objects While Resizing" is disabled after programmatically disabling scaling and then reenabling it for a single object
339553—Under certain conditions, wiring a mismatching data type to a Property Node input does not cause a broken run arrow
339661—Using the Export to CSlipboard method with a Mixed Signal Graph causes LabVIEW to crash
342148—Using a Boolean reference as the first item in a cluster can cause LabVIEW to crash
346295—Cannot create negative user-defined error codes in the Edit Error Code Assistant
347249—Keeping the mouse over the drop-down menu for a combo box causes high CPU usage
352625—Creating patches for an installer leaves multiple entries in Add/Remove Programs
354737—Running eight remote front panel executables on the same port on the same computer causes significant performance degradation
354827—Polymorphic VIs break the wires connected to their outputs when switching between a specific type and Automatic
354829—MathScript Node hangs using certain data sets for linear and cubic 2D interpolation
355198—The Revision History dialog always appears when building an executable containing LabVIEW classes even if they are saved
355966—Changes to typedef enum sometimes do not prompt affected open VIs to save
356466—Stopping VIs and immediately closing project may crash LabVIEW
357219—Pasting into the Icon Editor stretches the clipboard image in the x and y directions
358049—When a specific VI is opened and closed, LabVIEW remains in the task bar, with no windows open
359369—Application Font change not applied correctly when pasting text
360520—Crash when dropping a cluster with a disabled table into an empty array control
360757—Deploying a project created with the Actor Framework template makes LabVIEW unresponsive
361635—Importing strings to a cluster containing two or more tables throws an error
361636—Ignore Timestamp property does not work for Mixed Signal Graphs
361793—I/O tags with names that are identical except for case behave differently in a built application
362742—Updating multiple shared variables' Networking Published: Binding Project Path crashes LabVIEW
362812—Quit LabVIEW primitive does not work in subVIs called by an Asynchronous Call by Reference function
363363—Undo does not work for the VI Properties dialog Reentrancy setting
364154—Cross-linking can occur if you use a sample project that contains an FPGA target before installing the LabVIEW FPGA Module
364607—Invalid Network VISA reference causes DAQmx calls to slow in different loop
364643—Cursor does not associate with correct plot when using Cursor.Plot property with waveforms of different scales
365087—Register Event Callback crashes LabVIEW when wired to front panel object
366427—.NET property exceptions are not propagated by the error wire if called with a LabVIEW Property Node
367445—Source distribution of a class that uses dynamic dispatch can become broken looking for a missing subVI
369125—Shortcut menu does not allow the user to select items using the right mouse button
369472—Polymorphic VIs lose their icons when built into packed libraries
369537—Trying to set the "Active Bus" property on a Digital Waveform Graph crashes LabVIEW
369691—LabVIEW crashes if a Plot Visibility Checkbox of a Silver Waveform Graph is customized
369833—Draw VIs sometimes create corrupt PNG images when used with the LV Image to PNG Data VI
369872—Polymorphic VIs are not password-protected when built into source distributions
371030—A Waveform Graph incorrectly shows more peak plots when doing peak detection in combination with certain bar plot styles
372390—Hermite Interpolation 1D VI does not correctly interpolate certain data sets
373396—Sub-diagram labels that have been resized do not maintain their size when you edit them
373399—Resizing a sub-diagram label and bolding text within it bolds other text on the block diagram
374196—A Call Library Function Node referencing a function that does not exist within an existing DLL attempts to load despite being in a Diagram Disable structure
375002—Old library icon template persists on lower layer of VI icon after making library icon changes
375760—Displaying transposed array data on a Waveform Chart typedef causes crash during execution
375872—Crash when setting a floating-point numeric control to Inf, -Inf, or NaN when the control is configured for relative time display format
376574—Launching the Getting Started Window repeatedly can launch a blank VI instead of the Getting Started Window
376714—Using the Merge VIs utility with VIs that contain a tab control causes LabVIEW to hang
377021—Primitives are not correctly overloaded for Silver Matrix controls
378888—The Mixed Signal Graph does not correctly label plots in LabVIEW 2012
378947—MD5Checksum File VI returns the wrong value for files larger than 4GB
379023—Items with colons in their localized names do not drop with Quick Drop in LabVIEW German
379095—Changing display format on an EXT indicator produces an "End of file encountered" dialog
379444—Register Event Callback does not work in LabVIEW 2012 Base Development System
380475—Data returned from a LabVIEW built .NET Assembly that unbundles a cluster is incorrect
380741—Array Subset function can add an extra value to the output array when used on a fixed-sized array
381638—Waveform chart x-axis scales incorrectly when Plot Area scrolls for new data
381707—The Render to Image method for 3D picture controls demonstrates slow performance
382333—The Match Regular Expression VI in LabVIEW 2012 on Linux crashes when the screen color depth is set to 16-bit
382668—Silver Multicolumn Listbox has six blank cells when placed from palette
383351—LabVIEW crashes if a subVI front panel is continually open and closed while its graphs are updated
383525—The "auto-detect the storage format" option of the Open Data Storage Express VI only works the first time you wire the VI
384576—NI SSL Libraries not installed for LabVIEW Runtime Engine on OS X
384767—Performance of Error Cluster From Error Code VI is hurt by VI Server calls
385212—Adding and removing a registry key from a build specification can cause the build specification to become corrupt
385247—Custom Waveform Graphs display NaN values incorrectly
385317—LabVIEW crashes when a Value Change user event is registered on a Panel GOjbect
385324—The Max&Min VI incorrectly compares NaN values in arrays of 16 or more
386813—Changing an Error Cluster constant to a control, then undoing the change, causes the front panel to hang
387768—SubVI execution speed is reduced if SubVI contains a Case structure with an unwired 2D string array tunnel
388083—LabVIEW crashes when you open Profile Performance and Memory window from a library
388419—Registering a cluster containing an array of user-defined events crashes LabVIEW 64-bit
389295—LabVIEW 2012 SP1 breaks custom prototypes in DLLs that contain LabVIEW classes
389991—Memory leak when calling LabVIEW DLLs from C with new threads
390386—LabVIEW HTTP Client does not implement Curl Rewind, causing authentication errors for auth-basic
390673—Crash when you open a VI containing a Time Domain Math Express VI in LabVIEW 2012 after saving the VI for 2011
390908—Crash on Windows 64-bit when X input of the Cubic Spline Fit VI is empty
391285—NI Variable Engine tagsrv.exe cannot handle illegal characters in OPC Tag names
391783—Compiler error: "copy cvt str/pict/tag, csrc=0x21" on conditional auto-indexing tunnel
394001—Timestamp data exported to DIAdem from graphs is incorrect
395404—Reading MixedSignalGraph.PlotClassName causes Access Violation crash
395901—Compiler error: "maxmin only minip?" when LabVIEW 2011 VI is compiled in LabVIEW 2012
396062—After upgrading VI to 2012 SP1 the Round to Nearest function sometimes produces incorrect value if debugging is not allowed
396305—Conversion from EXT to U64 is incorrect for integers greater than 53 bits, when the top 53 bits are set
396603—The X-axis tick marks on strip charts move further than data points when updating
396984—Sequential For Loops sometimes execute incorrectly when VI property "Allow Debugging" is disabled
403235—DAbort 0xF50EFD7B in MemoryManager.cpp when auto-indexing a 2D waveform
403284—Execution speed does not return to normal after removing debug probes
403386—Using a property node to rapidly read the references to the variables deployed on a target introduces memory leak
404117—Cannot create Shared Variable if properties are copied from a Shared Variable inside a virtual folder
Important InformationCopyright© 2004–2013 National Instruments. All rights reserved.Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.End-User License Agreements and Third-Party Legal NoticesFor end-user license agreements (EULAs) and copyright notices, conditions, and disclaimers, including information regarding certain third-party components used in LabVIEW, refer to the Copyright topic of the LabVIEW Help.TrademarksLabVIEW, National Instruments, NI, ni.com, LabVIEW, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks.Other product and company names mentioned herein are trademarks or trade names of their respective companies.PatentsFor patents covering the National Instruments products/technology, refer to the appropriate location: Help» Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.
求R屏补丁{:soso_e102:}
页:
[1]