石鑫华视觉 发表于 2013-8-7 13:36:28

NI LabVIEW 2013 Win32ENG 32位LV2013英文版下载

Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html

视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html

NI LabVIEW 2013 Win32ENG 32位LV2013英文版下载

文件大小: 1404691232 字节 (1.31 GB)
修改日期: 2013-08-08 10:50
MD5: 0b0b5ef75faa918b06a6314246863173
SHA1: 740fa62e93c395f7d3bf4e470565fddce24beb96
SHA256: e9cbebb9748dc0f54ea3d37400ae825647659dee63ed490f70b33ef9b8bd2f3a
CRC32: 3d6cb5c1
百度网盘下载:
链接: 请注册视觉论坛会员登录后购买附件下载查看
提取码: 请购买附件下载查看

NI官方下载地址(可能无效或无法下载完成):
请购买附件下载查看
下载器:
请购买附件下载查看


LabVIEW 2013 Readme for WindowsVersion 13.0.0June 2013This file contains important information about LabVIEW 2013 for Windows, including installation instructions, a partial list of bugs fixed for LabVIEW 2013, and known issues.Refer to the National Instruments website for the latest information about LabVIEW 2013.Refer to the labview\readme directory for readme files about LabVIEW add-ons, such as modules and toolkits.System RequirementsInstallation InstructionsKnown IssuesLabVIEW 2013 (64-bit)Additions to the LabVIEW HelpBug FixesAccessing the HelpFinding ExamplesAutomating the Installation of NI ProductsHow to Use NI Software with Microsoft Windows 8NI Software Support for Microsoft Windows Vista, Windows XP, and Windows Server 2003System Requirements
WindowsRun-Time EngineDevelopment Environment
ProcessorPentium III/Celeron 866 MHz or equivalentPentium 4M or equivalent
RAM256 MB1 GB
Screen Resolution1024 x 768 Pixels1024 x 768 Pixels
Operating SystemWindows 8/7/Vista (32-bit and 64-bit)
Windows XP SP3 (32-bit)
Windows Server 2008 R2 (64-bit)
Windows Server 2003 R2 (32-bit)Windows 8/7/Vista (32-bit and 64-bit)
Windows XP SP3 (32-bit)
Windows Server 2008 R2 (64-bit)
Windows Server 2003 R2 (32-bit)
Disk Space382 MB3.5 GB (includes default drivers from the NI Device Drivers DVD)
Color PaletteN/ALabVIEW and the LabVIEW Help contain 16-bit color graphics. LabVIEW requires a minimum color palette setting of 16-bit color.
Temporary Files DirectoryN/ALabVIEW uses a directory for storing temporary files. National Instruments recommends that you have several megabytes of disk space available for this temporary directory.
Adobe ReaderN/AYou must have Adobe Reader installed to search PDF versions of all LabVIEW manuals.
NoteThe following list describes restrictions for using LabVIEW on Windows:
[*]LabVIEW does not support Windows 2000/NT/Me/98/95 or Windows XP x64.
[*]You cannot access LabVIEW using a Guest account on Windows.

Installation InstructionsDepending on whether you are installing LabVIEW for the first time or upgrading from a previous version, refer to one of the following documents for information about installing LabVIEW:
[*]LabVIEW Installation Guide—Includes information about installing LabVIEW, modules and toolkits, drivers, and hardware.
[*]LabVIEW Upgrade Notes—Includes information about protecting existing VIs and projects before you install a new version of LabVIEW, as well as upgrade and compatibility issues and a complete list of new features in LabVIEW 2013.
You can access the LabVIEW Installation Guide and the LabVIEW Upgrade Notes at ni.com as well as on the installation media.NoteIf you purchased this product with an NI Software Suite or NI Product Bundle, use the installation media that shipped with your purchase to install this product.LabVIEW Updates and NotificationsNational Instruments posts information about critical updates and security notifications on ni.com. Visit ni.com/info and enter Info Code updates to access this information.Known IssuesYou can access the software and documentation known issues list online. Refer to the National Instruments website for an up-to-date list of known issues in LabVIEW 2013.LabVIEW 2013 (64-bit)When run on Windows (64-bit), LabVIEW 2013 (64-bit) provides access to more memory than a 32-bit operating system or a 32-bit application can provide. LabVIEW 2013 (64-bit) includes nearly all of the development environment features of LabVIEW 2013 (32-bit).Refer to the National Instruments website for information about obtaining a copy of LabVIEW 2013 (64-bit).Supported HardwareLabVIEW 2013 (64-bit) supports many hardware devices. Refer to the National Instruments website for information about drivers compatible with LabVIEW 2013 (64-bit). For GPIB devices, you must use at least NI-488.2 2.6 for Windows. Refer to the specific hardware documentation for more information about compatibility with LabVIEW 2013 (64-bit).Supported ModulesLabVIEW 2013 (64-bit) supports only the NI Vision Development Module. Refer to the Vision Development Module documentation for more information. No additional modules support LabVIEW 2013 (64-bit).Additions to the LabVIEW HelpThe following list contains additional changes to LabVIEW that are not included in the LabVIEW Help, the LabVIEW Upgrade Notes, or both:
[*]Because LabVIEW 2013 may apply different compiler optimizations on different machines, you may need to perform additional steps to guarantee that a built application contains the same binary contents when built on different machines. Refer to the National Instruments website for more information about reproducing builds in LabVIEW 2013.
[*]If you create a VI that overrides a property accessor VI in a parent LabVIEW class, you must provide the same name and folder path in the property definition folders for both the child and parent classes.
Bug FixesThe following items are the IDs and titles of a subset of issues fixed in LabVIEW 2013. This is not an exhaustive list of issues fixed in the current version of LabVIEW. If you have a CAR ID, you can search this list to validate the issue has been fixed.
IDLegacy IDFixed Issue
3960449UBP4LEWrite to Clipboard Method consumes 100% of CPU for several minutes
439314GPF7QYESave Report to File.vi copies images from Temp rather than moving them
91672477M7K00Large amounts of data in combo box can appear to hang LabVIEW
136939—Dragging an unsaved VI from one project to another, and then closing the original project without saving corrupts the VI
138552—Load VRML File.vi missing "error in" terminal
148149—Event Structure cases can incorrectly remap to other dynamic events
214989—Dropping a System OK button silently removes any existing key binding for the <Return> key
221251—Shared Variable values discarded after system restart
233963—Service Locator does not work when installed to a path containing stress characters
240362—Image in Header or Footer.vi created HTML-files with one additional unwanted '<' character
242214—LabVIEW does not marshal .NET objects, so you cannot make a LabVIEW .NET assembly with a usable .NET refnum in the connector pane
248755—Zoom, pan, and rotate sometimes cause 3D objects to move in 3D Scene Displays
253088—Programmatic tab view changes sometimes fail if front panel controls are being updated with property nodes
256978—Custom Font Setting tokens in LabVIEW.ini file are overwritten when you modify any other part of the INI file
279047—Coercing a cluster containing a cluster to a variant can cause the inner cluster to have its labels change
280941—DWarn: ProjectItem.cpp line 8914 sometimes thrown when using auto-populating folders
287984—lvanlys.dll fails to load on an 8 core processor
288741—Non-handled, registered dynamic events reset the Event structure timeout
294464—Connected PSP property returns error on Shared Variables that have write only access
300375—Scan From String returns error when using %y%m formatting with 2 digit years
301753—SMTP Email Send Message VI: Subject line with more than 45 connected characters causes error
303503—When a LVM file is read by the Read from Measurement File Express VI, the Y Unit attribute is ignored
306025—Changing the front properties of a front panel object affects all objects created after it
309897—Scan from String incorrectly parses a string containing SI notation
312458—Fatal Internal Error: "proptype.cpp" sometimes displayed when programmatically exiting LabVIEW
312533—Private member VIs of a library can be exported in .NET interop assemblies
315663—Files inside a NIER Report have the incorrect date
317314—LabVIEW "Terminal" based web services don't display more than 6 digits of precision
318263—Changing a type def text ring control to a constant causes the display format to change to floating point
319888—Using NaN in Y array of XY Graph causes line not to plot
321518—Nested source-only type-defined clusters may not propagate changes to calling VIs
322705—Find and Replace text sometimes does not find all instances of text
323078—Silver XY Graph's legend does not snap to upper-right corner of graph when control is set to fit to pane
325150—The tip strips for the Variant To/From Element nodes on the In Place Element structure are missing
330806—Incorrect time stamp plotted when using Express VIs
331293—Font changes to XY Graph affect non-selected controls
334314—Creating an Override VI for a child class that has a parent in a Packed Project Library gives error 1035
334661—Pane setting "Scale Objects While Resizing" is disabled after programmatically disabling scaling and then reenabling it for a single object
339553—Under certain conditions, wiring a mismatching data type to a Property Node input does not cause a broken run arrow
339661—Using the Export to CSlipboard method with a Mixed Signal Graph causes LabVIEW to crash
342148—Using a Boolean reference as the first item in a cluster can cause LabVIEW to crash
346295—Cannot create negative user-defined error codes in the Edit Error Code Assistant
347249—Keeping the mouse over the drop-down menu for a combo box causes high CPU usage
352625—Creating patches for an installer leaves multiple entries in Add/Remove Programs
354737—Running eight remote front panel executables on the same port on the same computer causes significant performance degradation
354827—Polymorphic VIs break the wires connected to their outputs when switching between a specific type and Automatic
354829—MathScript Node hangs using certain data sets for linear and cubic 2D interpolation
355198—The Revision History dialog always appears when building an executable containing LabVIEW classes even if they are saved
355966—Changes to typedef enum sometimes do not prompt affected open VIs to save
356466—Stopping VIs and immediately closing project may crash LabVIEW
357219—Pasting into the Icon Editor stretches the clipboard image in the x and y directions
358049—When a specific VI is opened and closed, LabVIEW remains in the task bar, with no windows open
359369—Application Font change not applied correctly when pasting text
360520—Crash when dropping a cluster with a disabled table into an empty array control
360757—Deploying a project created with the Actor Framework template makes LabVIEW unresponsive
361635—Importing strings to a cluster containing two or more tables throws an error
361636—Ignore Timestamp property does not work for Mixed Signal Graphs
361793—I/O tags with names that are identical except for case behave differently in a built application
362742—Updating multiple shared variables' Networking Published: Binding Project Path crashes LabVIEW
362812—Quit LabVIEW primitive does not work in subVIs called by an Asynchronous Call by Reference function
363363—Undo does not work for the VI Properties dialog Reentrancy setting
364154—Cross-linking can occur if you use a sample project that contains an FPGA target before installing the LabVIEW FPGA Module
364607—Invalid Network VISA reference causes DAQmx calls to slow in different loop
364643—Cursor does not associate with correct plot when using Cursor.Plot property with waveforms of different scales
365087—Register Event Callback crashes LabVIEW when wired to front panel object
366427—.NET property exceptions are not propagated by the error wire if called with a LabVIEW Property Node
367445—Source distribution of a class that uses dynamic dispatch can become broken looking for a missing subVI
369125—Shortcut menu does not allow the user to select items using the right mouse button
369472—Polymorphic VIs lose their icons when built into packed libraries
369537—Trying to set the "Active Bus" property on a Digital Waveform Graph crashes LabVIEW
369691—LabVIEW crashes if a Plot Visibility Checkbox of a Silver Waveform Graph is customized
369833—Draw VIs sometimes create corrupt PNG images when used with the LV Image to PNG Data VI
369872—Polymorphic VIs are not password-protected when built into source distributions
371030—A Waveform Graph incorrectly shows more peak plots when doing peak detection in combination with certain bar plot styles
372390—Hermite Interpolation 1D VI does not correctly interpolate certain data sets
373396—Sub-diagram labels that have been resized do not maintain their size when you edit them
373399—Resizing a sub-diagram label and bolding text within it bolds other text on the block diagram
374196—A Call Library Function Node referencing a function that does not exist within an existing DLL attempts to load despite being in a Diagram Disable structure
375002—Old library icon template persists on lower layer of VI icon after making library icon changes
375760—Displaying transposed array data on a Waveform Chart typedef causes crash during execution
375872—Crash when setting a floating-point numeric control to Inf, -Inf, or NaN when the control is configured for relative time display format
376574—Launching the Getting Started Window repeatedly can launch a blank VI instead of the Getting Started Window
376714—Using the Merge VIs utility with VIs that contain a tab control causes LabVIEW to hang
377021—Primitives are not correctly overloaded for Silver Matrix controls
378888—The Mixed Signal Graph does not correctly label plots in LabVIEW 2012
378947—MD5Checksum File VI returns the wrong value for files larger than 4GB
379023—Items with colons in their localized names do not drop with Quick Drop in LabVIEW German
379095—Changing display format on an EXT indicator produces an "End of file encountered" dialog
379444—Register Event Callback does not work in LabVIEW 2012 Base Development System
380475—Data returned from a LabVIEW built .NET Assembly that unbundles a cluster is incorrect
380741—Array Subset function can add an extra value to the output array when used on a fixed-sized array
381638—Waveform chart x-axis scales incorrectly when Plot Area scrolls for new data
381707—The Render to Image method for 3D picture controls demonstrates slow performance
382333—The Match Regular Expression VI in LabVIEW 2012 on Linux crashes when the screen color depth is set to 16-bit
382668—Silver Multicolumn Listbox has six blank cells when placed from palette
383351—LabVIEW crashes if a subVI front panel is continually open and closed while its graphs are updated
383525—The "auto-detect the storage format" option of the Open Data Storage Express VI only works the first time you wire the VI
384576—NI SSL Libraries not installed for LabVIEW Runtime Engine on OS X
384767—Performance of Error Cluster From Error Code VI is hurt by VI Server calls
385212—Adding and removing a registry key from a build specification can cause the build specification to become corrupt
385247—Custom Waveform Graphs display NaN values incorrectly
385317—LabVIEW crashes when a Value Change user event is registered on a Panel GOjbect
385324—The Max&Min VI incorrectly compares NaN values in arrays of 16 or more
386813—Changing an Error Cluster constant to a control, then undoing the change, causes the front panel to hang
387768—SubVI execution speed is reduced if SubVI contains a Case structure with an unwired 2D string array tunnel
388083—LabVIEW crashes when you open Profile Performance and Memory window from a library
388419—Registering a cluster containing an array of user-defined events crashes LabVIEW 64-bit
389295—LabVIEW 2012 SP1 breaks custom prototypes in DLLs that contain LabVIEW classes
389991—Memory leak when calling LabVIEW DLLs from C with new threads
390386—LabVIEW HTTP Client does not implement Curl Rewind, causing authentication errors for auth-basic
390673—Crash when you open a VI containing a Time Domain Math Express VI in LabVIEW 2012 after saving the VI for 2011
390908—Crash on Windows 64-bit when X input of the Cubic Spline Fit VI is empty
391285—NI Variable Engine tagsrv.exe cannot handle illegal characters in OPC Tag names
391783—Compiler error: "copy cvt str/pict/tag, csrc=0x21" on conditional auto-indexing tunnel
394001—Timestamp data exported to DIAdem from graphs is incorrect
395404—Reading MixedSignalGraph.PlotClassName causes Access Violation crash
395901—Compiler error: "maxmin only minip?" when LabVIEW 2011 VI is compiled in LabVIEW 2012
396062—After upgrading VI to 2012 SP1 the Round to Nearest function sometimes produces incorrect value if debugging is not allowed
396305—Conversion from EXT to U64 is incorrect for integers greater than 53 bits, when the top 53 bits are set
396603—The X-axis tick marks on strip charts move further than data points when updating
396984—Sequential For Loops sometimes execute incorrectly when VI property "Allow Debugging" is disabled
403235—DAbort 0xF50EFD7B in MemoryManager.cpp when auto-indexing a 2D waveform
403284—Execution speed does not return to normal after removing debug probes
403386—Using a property node to rapidly read the references to the variables deployed on a target introduces memory leak
404117—Cannot create Shared Variable if properties are copied from a Shared Variable inside a virtual folder
Accessing the HelpRefer to the LabVIEW Help, accessible by selecting Help»LabVIEW Help from LabVIEW, for more information about LabVIEW 2013.Finding ExamplesSelect Help»Find Examples from LabVIEW to launch the NI Example Finder.Automating the Installation of NI ProductsYou can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes. However, starting with the August 2012 releases (products using NI Installers version 3.1 or later), you may need to perform additional steps before or during a silent installation of NI software.If the NI product you are installing uses Microsoft .NET 4.0, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.0 separately before you install NI software.For more information, refer to the following KnowledgeBase articles:
[*]For more information on silent installations of individual NI products, refer to KB 4CJDP38M, Automating the Installation of a Single Installer.
[*]For more information on silent installations of suited NI products, such as NI Developer Suite, refer to KB 4GGGDQH0, Automating the Installation of a Suited Installer.
[*]To determine what version of NI Installers your product contains, refer to KB 4CJDR18M, How Can I Determine the Type and Version of My National Instruments Installer?.
How to Use NI Software with Microsoft Windows 8When you install National Instruments software on Microsoft Windows 8, you will notice a few additional tiles on the Start screen, including shortcuts to NI application software products such as NI LabVIEW, Measurement & Automation Explorer (MAX), and the new NI Launcher.Using NI LauncherNI Launcher helps you find and launch installed NI products. It provides you with a method of finding NI products similar to the Start menu in previous versions of Microsoft Windows. To use NI Launcher, click the NI Launcher tile on the Start screen. NI Launcher launches the desktop and opens a menu containing a list of NI products. Click any NI product to launch it.NoteMAX does not appear as a desktop shortcut when installed on Microsoft Windows 8. You can launch MAX either from the Start screen or from within NI Launcher.
Pinning Frequently Used ApplicationsFor convenience, you can pin your most-used NI applications, such as MAX, to either the Start screen or the Taskbar on the desktop, as necessary:
Current ApplicationIcon LocationPin to Action
Windows 8 DesktopDesktop TaskbarRight-click application and select Pin to Taskbar
Windows 8 DesktopStart screenRight-click application and select Pin to Start
Windows 8 Start screenDesktop TaskbarRight-click application and select Pin to taskbar from the menu bar on the bottom of the screen
Finding All ProgramsIf you want to find a particular application or related files, such as documentation files, from the Start screen, you can access all installed files by right-clicking anywhere on the Start screen and selecting All apps. A list of all installed software and related files appears, in alphabetical order by creator or type.For more information about NI support for Windows 8, visit ni.com/windows8.LabVIEW Drops Support for Microsoft Windows Vista, Windows XP, and Windows Server 2003 in 2016National Instruments LabVIEW will drop support for Microsoft Windows Vista, Windows XP, and Windows Server 2003 as of July 1, 2016. Versions of LabVIEW that ship after July 1, 2016 will not install or run on Windows Vista, Windows XP, or Windows Server 2003. For detailed information about NI application software product life cycles, visit ni.com/info and enter one of the following Info Codes:
ProductInfo Code
NI LabVIEWlifecycle
NI LabWindows™/CVI™cvi_lifecycle
NI Measurement Studiomstudiolifecycle
NI TestStandtslcp
NI DIAdemddlcp
NI SignalExpressselcp
NI VeriStandnivslifecycle
Important InformationCopyright© 2004–2013 National Instruments. All rights reserved.Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.End-User License Agreements and Third-Party Legal NoticesYou can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
[*]Notices are located in the <National Instruments> directories.
[*]EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory.
[*]Review <National Instruments>\_Legal Information.txt for information on including legal information in installers built with NI products.
TrademarksRefer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.PatentsFor patents covering the National Instruments products/technology, refer to the appropriate location: Help» Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.
页: [1]
查看完整版本: NI LabVIEW 2013 Win32ENG 32位LV2013英文版下载

LabVIEW HALCON图像处理入门教程(24.09)
石鑫华机器视觉与LabVIEW Vision图像处理PDF+视频教程11种全套
《LabVIEW Vision函数实例详解2020-2024》教程-NI Vision所有函数使用方法介绍,基于NI VISION2020,兼容VDM21/22/23/24