LabVIEW 2011SP1 FPGA Compile Farm Toolkit Win32Eng LabVIEW2011SP1FPGA集群编译工具包FPGA-CFT2011SP1
Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html
LabVIEW 2011SP1 FPGA Compile Farm Toolkit Win32Eng LabVIEW2011SP1FPGA集群编译工具包FPGA-CFT2011SP1
LabVIEW FPGA Compile Farm工具包可帮助您创建现场服务器,轻松管理FPGA编译。
LabVIEW FPGA Compile Farm工具包可帮助您创建现场服务器,轻松管理FPGA编译。用户可根据需要连接多台编译计算机;中央服务器软件负责管理并行编译和队列之外的集群部署(farming)。为了帮助用户缩短FPGA编译时间,该工具包还可支持Linux编译服务器计算机。
百度网盘下载地址(限速,请开会员或使用破解限速工具):
FPGA-CFT2011SP1版我方未下载到资源,敬请谅解。
NI官方下载地址(可能无效或无法下载完成):
FPGA-CFT2011SP1版我方未下载到资源,敬请谅解。
LabVIEW 2011 SP1 FPGA Module ReadmeVersion 11.0.1December 2011This file contains important information about the LabVIEW FPGA Module.InstallationYou can install all of your LabVIEW products—including the FPGA Module–using the LabVIEW 2011 Platform DVDs. You can find installation instructions for the FPGA Module along with activation instructions in the following locations:
[*]LabVIEW FPGA Module Release and Upgrade Notes, which are available in your FPGA Module software kit or online at ni.com/manuals.
[*]LabVIEW Release Notes, which are available in your LabVIEW software kit.
[*]LabVIEW 2011 Platform DVDs Readme, which is available on the top-level of LabVIEW Platform DVD 1.
To request additional LabVIEW 2011 Platform DVDs, refer to the National Instruments Web site.Note: If you purchased this product with an NI Software Suite or NI Product Bundle, use the installation media that shipped with your purchase to install this product.Known IssuesYou can access the software and documentation known issues list online. Refer to the National Instruments Web site for an up-to-date list of known issues in the FPGA Module.Bug FixesThe following items are the IDs and titles of a subset of issues fixed in the LabVIEW 2011 SP1 FPGA Module.
IDFixed Issue
321818FPGA VI causes "ngdbuild.exe has stopped working" error.
318512Compile Worker fails to start when using the older of two versions of installed LabVIEW FPGA.
315613Simulation export build fails on localized European OSes.
313939Statistics Function can have results that overflow.
311252Xilinx compiler runs out of memory.
308756Potential data corruption when using FlexRIO DRAM primitive or cRIO XNET Module.
305700Mutation of controls connected to terminals of DSP48E is incorrect from 2010 to 2011.
Copyright© 2003–2011 National Instruments Corporation. All rights reserved.I. Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.II. Third-Party Copyright NoticesThe SharpZipLib_Notice.pdf file contains a third-party copyright notice for third-party components used by certain FPGA Module features. The following directory is the default installation location for the file, but the location might vary depending on the configuration of the local computer:
\National Instruments\LabVIEW 2011\FPGA\Legal\The Python_2.5_notice.pdf file contains a third-party copyright notice for third-party components used by certain FPGA Module features. The following directory is the default installation location for the file, but the location might vary depending on the configuration of the local computer:
\National Instruments\LabVIEW 2011\FPGA\Legal\TrademarksNational Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks.Xilinx® is a registered trademark of Xilinx, Inc.Other product and company names mentioned herein are trademarks or trade names of their respective companies.PatentsFor patents covering the National Instruments products/technology, refer to the appropriate location: Help» Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.