LabVIEW 2013 FPGA IP Builder Win32Eng LabVIEW2013 FPGA IP生成器IPB2013
Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html
LabVIEW 2013 FPGA IP Builder Win32Eng LabVIEW2013 FPGA IP生成器IPB2013
自动优化LabVIEW FPGA VI,实现性能和资源利用率目标
最大程度减少LabVIEW桌面应用和FPGA算法实现之间的代码更改
快速进行设计权衡,无需更改算法
通过将算法代码与设计指令分开存储来提高IP复用率
借助LabVIEW FPGA模块的附加工具——NI LabVIEW FPGA IP Builder,用户可结合高层次综合(HLS)技术和LabVIEW的强大功能,轻松优化LabVIEW FPGA VI的性能和资源利用率。
用于基于FPGA的应用(如机器视觉、控制和仿真、声音和振动、数字信号处理和通信系统)的滤波器、编码器/解码器和其他分析功能可通过LabVIEW FPGA IP Builder自动进行优化,无需用户掌握反而会降低代码可移植性和可读性的硬件描述语言(HDL)或高级优化技巧。
该附加工具可帮助用户使用LabVIEW图形化数据流语言来描述算法。 用户可利用代码内的数组和嵌套循环,同时仍可获得高度优化的用于基于NI FPGA的硬件的算法。 该工具根据用户提供的指令工作,这些指令可捕捉设计限制,指导用户使用LabVIEW FPGA IP Builder的代码生成器。 该工具还采用前沿的HLS技术来帮助用户应用先进的优化技术(如流水线、资源复用、循环展开),生成节省资源和时间的FPGA IP。
借助LabVIEW FPGA IP Builder,用户可得到匹配或优于通过手动LabVIEW FPGA设计优化得到的结果,并专注于算法的高层设计。 由于算法代码和设计指令分开存储,用户可快速创建用于同一IP的多个指令集,以便进行设计权衡,并可轻松复用IP以来满足新设计要求。 该工具可预测和优化资源(如乘法器和块RAM)的使用,帮助用户及时地估计资源的使用和时间进程。 LabVIEW FPGA IP Builder生成的IP自动包含在一个IP集成节点中,用于LabVIEW FPGA设计过程中的单周期定时循环。
FPGA IP Builder工具包,仅找到独立安装的2012版和2013版。在2014~2019版之间,该IP生成器工具包则包含在FPGA模块中。在NI官方网站上有看到IPB2011SP1版的自述文件,但是无法找到相应的资源。再之前的版本,则无法确认是否有相应的IPB工具包。
百度网盘下载地址(限速,请开会员或使用破解限速工具):
请注册登录视觉论坛会员,购买附件查看
NI官方下载地址(可能无效或无法下载完成):
请注册登录视觉论坛会员,购买附件查看
LabVIEW 2013 FPGA IP Builder ReadmeVersion 13.0.0June 2013This file contains important information about the LabVIEW 2013 FPGA IP Builder.Overview
New Features and Changes
System Requirements
Supported FPGA Targets
Installation Instructions
Activation Instructions
Upgrade and Compatibility Issues
Known Issues
Bug Fixes
Accessing the Help
Finding Examples
Automating the Installation of NI Products
NI Software Support for Microsoft Windows Vista, Windows XP, and Windows Server 2003OverviewThe FPGA IP Builder enables you to create FPGA algorithms, interactively optimize the algorithms according to specific application requirements, and automatically generate efficient LabVIEW FPGA code.You must have the LabVIEW FPGA Module, the necessary Xilinx compilation tools, and NI-RIO installed on the local computer to use the FPGA IP Builder. Refer to the FPGA Module installation options on the LabVIEW Platform DVD, or your original media, for instructions on installing the FPGA Module and Xilinx compilation tools for LabVIEW. Refer to the NI Device Drivers DVD for instructions on installing NI-RIO.After you install the FPGA IP Builder, an IP Builder project item automatically appears when you add an FPGA target to a LabVIEW project. The FPGA IP Builder supports only a limited number of FPGA targets.New Features and ChangesThe 2013 release of the FPGA IP Builder includes the following new features and changes:
[*]Improved FPGA IP generation, leading to higher performance and lower resource usage
[*]Improved Directives Properties dialog box
[*]Context help for each directive
[*]Quick estimate and Thorough estimate options for estimating device utilization and timing performance
[*]Support for single-precision floating-point data type
[*]A limited number of functions
[*]New floating-point constants
[*]Support for integers, fixed-point numbers, and single-precision numbers as inputs for the Array Subset function and the Build Array function
[*]New Numeric functions:
[*]Divide
[*]Square Root
System RequirementsIn addition to the system requirements for the LabVIEW Development System, the FPGA IP Builder has the following requirements:
[*]2 GB free disk space, with 2 GB additional disk space for virtual memory
[*]LabVIEW 2013 Full or Professional Development System (32-bit)
[*]LabVIEW 2013 FPGA Module
[*]NI-RIO Device Drivers - August 2013
[*]Compilation Tools for FPGA Devices other than Virtex-II
NoteThe FPGA IP Builder does not support Windows 8.Refer to the LabVIEW Readme, LabVIEW FPGA Module Release and Upgrade Notes, and NI-RIO Device Drivers Readme for additional system requirements and supported operating systems.Supported FPGA TargetsThe FPGA IP Builder supports the following FPGA targets:
Device TypeTarget
CompactRIOcRIO-9081
cRIO-9082
cRIO-911x
Ethernet RIO**NI 9146
FlexRIOPXI-795xR
PXIe-796xR
IF Transceivers*PXIe-5641R
MXIe-RIO ChassisNI 9157
NI 9159
R SeriesPCIe, PXI-784xR
PCIe, PXI-785xR
Real-Time CompactRIO**cRIO-9075
cRIO-9076
cRIO-9081
cRIO-9082
cRIO-FRC II
Real-Time Single-Board RIO**sbRIO-9605
sbRIO-9606
sbRIO-9623
sbRIO-9626
sbRIO-9633
sbRIO-9636
Vector Signal Transceiver (VST)***PXIe-5644R
* Appears only if you install the NI-5640R instrument driver.
** Appears only if you add a top-level target in a project. Requires the LabVIEW Real-Time Module.
*** Appears only if you install the NI PXIe-5644R instrument driver.
Installation InstructionsDouble-click the setup.exe file in the root directory of the FPGA IP Builder installer and follow the instructions on the screen to install this product.Activation InstructionsComplete the following steps to activate the FPGA IP Builder.
[*]Install the FPGA IP Builder—Refer to the Installation Instructions section of this readme for information about installing the FPGA IP Builder.
[*]Locate your Serial Number—Your serial number uniquely identifies your purchase of NI software. You can find your serial number on the Certificate of Ownership included in your software kit. If your software kit does not include a Certificate of Ownership, you can find your serial number on the product packing slip or on the shipping label. For more information about finding serial numbers, visit ni.com/info and enter the Info Code SerialNumbers_en.
If you have a previous version of the application installed, you can find the serial number by selecting your product within NI License Manager (Start»All Programs»National Instruments»NI License Manager). You can also contact your local National Instruments branch. Refer to ni.com/niglobal for branch office contact information.
NoteThis release of the LabVIEW FPGA IP Builder is provided under a perpetual license, subject to earlier termination as provided in the license agreement for the software. If you are upgrading to this release from a previous release of the LabVIEW FPGA IP Builder software that you have licensed under a one-year or other limited term license, send an email to ipbuilder.activation@ni.com to receive assistance in switching to the perpetual license.
[*]Launch the NI Activation Wizard—The NI Activation Wizard guides you through the activation process. If you installed the FPGA IP Builder for the first time, the installer may launch the NI Activation Wizard for you. Otherwise, launch your software and choose to activate when prompted. If you are not prompted, perform the following steps:
[*]Launch NI License Manager by selecting Start»All Programs»National Instruments»NI License Manager.
[*]Select the FPGA IP Builder product name in the NI License Manager tree and click Activate on the toolbar.
[*]Follow the on-screen instructions to activate the FPGA IP Builder using the NI Activation Wizard.
NoteIf you encounter any difficulties when activating the FPGA IP Builder, send an email to ipbuilder.activation@ni.com to receive support.[*]Save your Activation Code for Future Use (optional)—NI Activation Wizard provides you with the option to receive an email confirmation of your activation code. If you reinstall your software on the same computer, the same activation code will work. To apply this activation code in the future, launch the NI Activation Wizard and select Apply one or more 20-character activation codes previously acquired for this computer.
Installing and Activating Software UpgradesIf you are upgrading or moving between software packages, in most cases you do not have to install additional software, as follows:
[*]Upgrading from an Evaluation Version to a Paid Version—If you are upgrading from an evaluation version to a paid version, you do not need to reinstall your software, even if the evaluation period has expired. Follow the prompts that appear when you launch your application or use NI License Manager to activate the software.
For information on how to use NI License Manager to activate software, refer to the NI License Manager Help, which you can access from the Help»Contents menu item in NI License Manager.Product RegistrationDuring activation, you may be prompted for your ni.com user ID and password in order to register your product. NI uses the contact information that you provide to ensure access to your service benefits, including technical support, software upgrades, and updates. If you are not prompted to register, you can visit ni.com/support, click the Product Registration link, and enter your registration information manually.License LimitationNational Instruments only permits you to use each FPGA IP Builder license on a single computer. Refer to the software end-user license agreement in the installer, the NI License Manager Help, or ni.com/legal/license for more information.Moving Software after ActivationActivation codes for the FPGA IP Builder are unique to each computer. To transfer your software to another computer, you will need a new activation code. To receive a new activation code when moving the software to another new computer, send an email to ipbuilder.activation@ni.com.Privacy PolicyNational Instruments respects your privacy. For more information about the National Instruments activation information privacy policy, go to ni.com/activate/privacy.Terms
activation codeA 20-character code that enables NI software to run on your computer, based on your serial number and computer ID. You receive and apply an activation code by completing the activation process.
computer IDA 16-character ID that uniquely identifies your computer, generated during the activation process. To find your computer ID, launch NI License Manager and click the Display Computer Information button.
serial numberAn alphanumeric string that uniquely identifies your purchase of a single copy of software, included in your software kit on your Certificate of Ownership, on the product packing slip, or on the shipping label.
National Instruments uses activation to better support evaluation of our software, to enable additional software features, and to support license management in large organizations. To find out more about National Instruments software licensing, visit ni.com/activate for frequently asked questions, resources, and technical support.Upgrade and Compatibility IssuesAfter you upgrade the FPGA IP Builder from version 2012 to version 2013, you might encounter the following compatibility issue:
[*]For the same directive configuration, the estimation and build reports that you obtained in version 2013 might be different from those you obtained in version 2012.
Known IssuesYou can access the software and documentation known issues list online. Refer to the National Instruments website for an up-to-date list of known issues in the FPGA IP Builder.Bug FixesThe following items are the IDs and titles of a subset of issues fixed in the FPGA IP Builder. This is not an exhaustive list of issues fixed in the current version of the FPGA IP Builder. If you have a CAR ID, you can search this list to confirm that the issue has been fixed.
IDFixed Issue
344412FPGA IP Builder converts some terminals to numeric controls and indicators
353425FPGA IP Builder might fail to apply the "Number of pipeline stages" directive
362036An estimation error occurs if the second-level subVI has unwired array controls
Accessing the HelpRefer to the LabVIEW Help, accessible by selecting Help»LabVIEW Help from LabVIEW, for more information about the FPGA IP Builder.Finding ExamplesSelect Help»Find Examples from LabVIEW to launch the NI Example Finder. LabVIEW examples for the FPGA IP Builder are located in the labview\examples\FPGAIPBuilder directory. You can modify an example VI to fit an application, or you can copy and paste from one or more examples into a VI that you create.Automating the Installation of NI ProductsYou can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes. However, starting with the August 2012 releases (products using NI Installers version 3.1 or later), you may need to perform additional steps before or during a silent installation of NI software.If the NI product you are installing uses Microsoft .NET 4.0, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.0 separately before you install NI software.For more information, refer to the following KnowledgeBase articles:
[*]For more information on silent installations of individual NI products, refer to KB 4CJDP38M, Automating the Installation of a Single Installer.
[*]For more information on silent installations of suited NI products, such as NI Developer Suite, refer to KB 4GGGDQH0, Automating the Installation of a Suited Installer.
[*]To determine what version of NI Installers your product contains, refer to KB 4CJDR18M, How Can I Determine the Type and Version of My National Instruments Installer?.
NI LabVIEW FPGA IP Builder Drops Support for Microsoft Windows Vista, Windows XP, and Windows Server 2003 in 2016National Instruments LabVIEW FPGA IP Builder will drop support for Microsoft Windows Vista, Windows XP, and Windows Server 2003 as of July 1, 2016. Versions of the FPGA IP Builder that ship after July 1, 2016 will not install or run on Windows Vista, Windows XP, or Windows Server 2003. For detailed information about NI application software product life cycles, visit ni.com/info and enter one of the following Info Codes:
ProductInfo Code
NI LabVIEWlifecycle
NI LabWindows™/CVI™cvi_lifecycle
NI Measurement Studiomstudiolifecycle
NI TestStandtslcp
NI DIAdemddlcp
NI SignalExpressselcp
NI VeriStandnivslifecycle
Important InformationCopyright© 2012–2013 National Instruments. All rights reserved.Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.End-User License Agreements and Third-Party Legal NoticesYou can find end-user license agreements (EULAs) and third-party legal notices in the following locations:
[*]Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories.
[*]EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory.
[*]Review <National Instruments>\_Legal Information.txt for information on including legal information in installers built with NI products.
TrademarksRefer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.PatentsFor patents covering the National Instruments products/technology, refer to the appropriate location: Help» Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.
页:
[1]