LabVIEW Instrument Design Libraries for High-Speed Serial Instruments 16.1 Runtime Win32Eng LabVIEW高速串行仪器设计库16.1运行版
Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html
LabVIEW Instrument Design Libraries for High-Speed Serial Instruments 16.1 Runtime Win32Eng LabVIEW高速串行仪器设计库16.1运行版
LabVIEW Instrument Design Libraries for High-Speed Serial Instruments软件可帮助您为PXI高速串行仪器创建应用程序。
LabVIEW Instrument Design Libraries for High-Speed Serial Instruments是LabVIEW的一个驱动软件,用于创建和开发高速串行应用程序。该软件用作为用户和供应商代码之间的接口,适用于主机和FPGA,并可实现仪器常见的功能。LabVIEW Instrument Design Libraries for High-Speed Serial Instruments软件还可帮助您将项目导出到Vivado设计套件中。
Win32Eng
16.1RTE
文件大小: 451979789 字节 (431.04 MB)
修改日期: 2017-04-25 06:05
MD5: d58648f1d237867b51e3f536dde9674a(官方正确)
SHA1: 69e1d359f31bf021e7364cdf1d627b78b28c17e7
SHA256: 12e20f80a9490123c9de08d9e59462c55613dc140c9e51dfc7c1c06e5818a393
CRC32: aeb66a97
百度网盘与NI官方下载地址:
NI LabVIEW 2016 Instrument Design Libraries for High Speed Serial Instruments 16.1 ReadmeNovember 2016Thank you for using NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1. This file contains important information about NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 and is organized into the following sections.OverviewNew FeaturesSupported HardwareSystem RequirementsApplication Development Environments (ADEs)Installed Software, Documentation, and ExamplesDocumentationSample ProjectsProduct Security and Critical UpdatesDriver Version Naming ChangesInstalling NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1Known Issues and Bug FixesAutomating the Installation of NI ProductsUsing NI Software with Microsoft Windows 10How to Use NI Software with Microsoft Windows 8.1Legal InformationOverviewNI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 allows you to develop high-speed serial applications for use with the PXIe-6591R, PXIe-6592R, and PXIe-7902 high-speed serial modules.New FeaturesNI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 includes the following new features.
[*]Support for the PXIe-7902 module
[*]1 Gigabit Ethernet sample project
NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.0 includes the following new features.
[*]Support for LabVIEW 2016
NI LabVIEW 2015 Instrument Design Libraries for High Speed Serial 15.5 includes the following new features.
[*]Phar Lap RT support
[*]10 Gigabit Ethernet sample project
Supported HardwareNI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 supports the following hardware devices:
[*]PXIe-6591R
[*]PXIe-6592R
[*]PXIe-7902
System RequirementsSupported Operating SystemsNote: The following system requirements apply to NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 software only. LabVIEW FPGA has separate system requirements. Refer to the LabVIEW Readme for these system requirements.NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 supports the following operating systems:
Operating System64-bit32-bit
Windows 10✓✓
Windows 8.1✓✓
Windows 7 Professional✓✓
Windows Server 2012 R2✓—
Windows Server 2008 R2✓—
Note: NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 does not support Windows Server non-R2 editions.NI recommends that you have the most recent service pack for your operating system installed.Minimum System Requirements
[*]Processor—Pentium 4 or equivalent
[*]RAM—2 GB
[*]A screen resolution of 800 x 600 with 256 colors
[*]Windows 10/8.1/7 or Windows Server 2008/2012 with all available critical updates and service packs
Application Development Environments (ADEs)The following table lists the NI application software versions, including service packs, supported by NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1.
NI Application SoftwareVersions Supported by NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1
NI LabVIEWLabVIEW 2016 32-bit1
LabVIEW FPGALabVIEW 2016 FPGA
1NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 supports running host code in LabVIEW 2016 64-bit.Installed Software, Documentation, and Examples
[*]<NIDocDir> is an alias for the following National Instruments file folder location: Users\Public\Public Documents\National Instruments
[*]<IVIROOTDIR32> is an alias for the following National Instruments file folder location:
[*](32-bit) Program Files\IVI Foundation\IVI\
[*](64-bit) Program Files (x86)\IVI Foundation\IVI\
Note$(IVIROOTDIR32) is configured as an environment variable on the target system.
If you upgraded an installation of IVI, your files may be located in the following location:
[*](32-bit) Program Files\IVI\
[*](64-bit) Program Files (x86)\IVI\
[*]<IVIROOTDIR64> is an alias for the following National Instruments file folder location:
[*](64-bit) Program Files\IVI Foundation\IVI\
Note$(IVIROOTDIR64) is configured as an environment variable on the target system.
DocumentationThe product documentation is available at ni.com/manuals and from Start»All Programs»National Instruments»High Speed Serial Instruments»High Speed Serial Instruments Documentation.To view these documents, you need to have Adobe Acrobat Reader installed. You can install the viewer from www.adobe.com/acrobat.The documentation set is composed of the following documents:
DocumentDescription
NI High Speed Serial Instruments HelpContains information about high-speed serial instrument device support. This book also provides instructions for using LabVIEW and the LabVIEW FPGA Module with high-speed serial modules.
High Speed Serial Instruments User ManualContains information about how to develop applications for your high-speed serial modules.
Getting started guide for your deviceContains software and hardware installation, MAX configuration, signal connection, and troubleshooting information for your high-speed serial module.
Specifications document for your deviceLists technical specifications for your high-speed serial module.
NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 Readme (this document)Contains information about supported hardware and operating systems, new features, fixed issues, and legal notices.
Sample ProjectsIn LabVIEW, you can use the NI Example Finder to search or browse examples. In LabVIEW, select Help»Find Examples to launch the NI Example Finder. The NI Example Finder offers two ways to access all installed LabVIEW example VIs and their descriptions:
[*]Click the Browse tab to locate modulation examples by task.
[*]Click the Search tab to search all installed examples by keyword.
The NI Example Finder is also available in LabWindows/CVI by selecting Help»Find Examples.Examples also are available online that demonstrate applications using high-speed serial instruments. Refer to ni.com/examples for these examples and for more information.Product Security and Critical UpdatesVisit ni.com/security to view and subscribe to receive security notifications about National Instruments products. Visit ni.com/critical-updates for information about critical updates from National Instruments.Driver Version Naming ChangesNI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 versions are aligned with the versions of major NI application software products. This alignment gives you information about the year the driver was released and the most recent software version the driver was designed to work with. Driver versions start with a two-digit year indicator: <;ProductName><Year-BasedVersion>. For example, NI LabVIEW 2016 Instrument Design Libraries 16.0 is the version released with LabVIEW 2016.Installing NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1Complete the following steps to install NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1.
[*]Install LabVIEW. Refer to the LabVIEW Installation Guide for installation instructions for LabVIEW and system requirements for the LabVIEW software. Refer to the LabVIEW Upgrade Notes for additional information about upgrading to the most recent version of LabVIEW for Windows.
[*]Documentation for LabVIEW is available at ni.com/manuals and from Start»All Programs»National Instruments»LabVIEW»LabVIEW Manuals.
[*]Install the LabVIEW FPGA Module. Refer to the LabVIEW FPGA Module Release and Upgrade Notes for installation instructions and information about getting started with the LabVIEW FPGA Module.
[*]Documentation for the LabVIEW FPGA Module is available at ni.com/manuals and from Start»All Programs»National Instruments»LabVIEW»LabVIEW Manuals.
[*]Install the NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 driver.
[*]Documentation for the NI LabVIEW 2016 Instrument Design Libraries for High-Speed Serial Instruments 16.1 driver is available at ni.com/manuals and by selecting Start»All Programs»National Instruments»High-Speed Serial Instruments»High-Speed Serial Instruments Documentation.
Note The niSi53xxClockConfig.dll file included as part of the NI LabVIEW Instrument Design Libraries for High-Speed Serial Instruments software may be used only in the use of the NI LabVIEW Instrument Design Libraries for High-Speed Serial Instruments software with the Silicon Labs device in the PXIe-6591R, PXIe-6592R, and PXIe-7902 products.Known Issues and Bug FixesYou can access the software and documentation known issues and bug fixes list online at ni.com.Automating the Installation of NI ProductsYou can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes. However, starting with the August 2012 releases (products using NI Installers version 3.1 or later), you may need to perform additional steps before or during a silent installation of NI software.For more information about automating the installation of NI products, refer to the following KnowledgeBase articles:
[*]For more information about silent installations of individual NI products, refer to KB 4CJDP38M, Automating the Installation of a Single Installer.
[*]For more information about silent installations of NI products in a suite, such as NI Developer Suite, refer to KB 4GGGDQH0, How Do I Automate the Installation of a Suited Installer?.
[*]To determine what version of NI Installers your product contains, refer to KB 4CJDR18M, How Can I Determine the Type and Version of My National Instruments Installer?.
Using NI Software with Microsoft Windows 10Microsoft Windows 10 is the latest version of the Windows operating system and features significant changes compared to previous versions. Windows 10 introduces several new capabilities and also combines features from both Windows 7 and Windows 8. For more information about NI support for Windows 10, visit ni.com/windows10.How to Use NI Software with Microsoft Windows 8.1When you install National Instruments software on Microsoft Windows 8.1, you will notice a few additional tiles in the Apps view, including shortcuts to NI application software products such as NI LabVIEW, Measurement & Automation Explorer (NI MAX), and NI Launcher.Using NI LauncherNI Launcher helps you find and launch installed NI products. It provides you with a method of finding NI products similar to the Start menu in previous versions of Microsoft Windows. To use NI Launcher, click the NI Launcher tile in the Apps view. NI Launcher launches the desktop and opens a menu containing a list of NI products. Click any NI product to launch it.
NoteNI MAX does not appear as a desktop shortcut when installed on Microsoft Windows 8.1. You can launch NI MAX either from the Apps view or from within NI Launcher.
Pinning Frequently Used ApplicationsFor convenience, you can pin your most-used NI applications, such as MAX, to either the Start screen or the Taskbar on the desktop, as necessary:
Current ApplicationIcon LocationPin to Action
Windows 8.1 DesktopDesktop TaskbarRight-click application and select Pin to Taskbar.
Windows 8.1 DesktopStart screenRight-click application and select Pin to Start.
Windows 8.1 Start screenDesktop TaskbarRight-click application and select Pin to taskbar from the menu bar on the bottom of the screen.
Finding All ProgramsIf you want to find a particular application or related files, such as documentation files, from the Start screen, you can access all installed files from the Apps view. To get to the Apps view, right-click anywhere on the Start screen and click the down arrow on the bottom left of the screen.For more information about NI support for Windows 8.1, visit ni.com/windows8.Legal InformationCopyright©2008–2016 National Instruments. All rights reserved.Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.End-User License Agreements and Third-Party Legal NoticesYou can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
[*]Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories.
[*]EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory.
[*]Review <National Instruments>\_Legal Information.txt for information on including legal information in installers built with NI products.
U.S. Government Restricted RightsIf you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.IVI Foundation Copyright NoticeContent from the IVI specifications reproduced with permission from the IVI Foundation.The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.TrademarksRefer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.PatentsFor patents covering the National Instruments products/technology, refer to the appropriate location: Help» Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.374806E-01
页:
[1]