LabVIEW 2021 Datalogging and Supervisory Control Module Runtime System x64Win10 32bitEng LabVIEW2021数据记录与监控模块运行时系统DSC2021RTS
Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html
LabVIEW 2021 Datalogging and Supervisory Control Module Runtime System x64Win10 32bitEng LabVIEW2021数据记录与监控模块运行时系统DSC2021RTS
LabVIEW数据记录和监控(DSC)模块适用于开发HMI/SCADA或高通道数数据记录应用程序。
LabVIEW数据记录和监控(DSC)模块是LabVIEW编程环境的一个附加软件。您可以使用此模块以及数十到数万个标签,快速开发分布式监测和控制系统。该模块包含将数据记录到网络历史数据库、跟踪实时和历史趋势、管理警报和事件、将LabVIEW实时终端和OPC设备联网到一个完整系统,以及为用户界面添加安全性等任务所需的工具。
LabVIEW 2021数据记录与监控模块运行时系统
发布日期
2021/8/13
包含的版本
2021Runtime System
受支持的操作系统
Windows 10 64-bit
Windows Server 2016 64-bit
Windows Server 2019 64-bit
语言
English
32ENG RTS
文件大小: 1128542208 字节 (1.05 GB)
修改日期: 2021-08-12 05:43
MD5: 7d17917775a2b301482f65d8b1e003da
SHA1: a3fbf9e71cdb4a7c9f47796e04bba2216c63bbbb
SHA256: de8ea2982f76021983f9fec2f0649f3c2fbe5602c61a568c2e055277f1ec7bc8
CRC32: 80ce3bf1
百度网盘和NI官方下载地址:
请注册视觉论坛会员登录后购买附件下载查看
LabVIEW 2021 Datalogging and Supervisory Control Runtime ReadmeJuly 2021This file contains installation instructions and compatibility information for LabVIEW Datalogging and Supervisory Control (DSC) Runtime.You can find more release information on ni.com.
[*]Release Notes: Known issues, bugs fixed since the last release, and other notes about this release
[*]Manuals: New features, behavior changes, and other documentation
OverviewSystem RequirementsSupported Operating SystemsInstallation InstructionsProduct Security and Critical UpdatesAutomating the Installation of NI ProductsUsing NI Software with Microsoft Windows 10Unsupported Windows Operating SystemsLegal InformationOverviewThe LabVIEW DSC Runtime allows you to run applications built with LabVIEW, the DSC Module, and the LabVIEW Application Builder on a computer without the DSC Module installed. The DSC Runtime contains components that enable the DSC Module features in the built applications.System RequirementsThe DSC Runtime has the following requirements:
[*]Depending on the components you choose to install, the computer must have the following amount of free disk space:
[*]1.0 GB free disk space if you install all components of the DSC Runtime except the Shared Variable Logging Support component
[*]2.5 GB free disk space if you install all components of the DSC Runtime
[*]At least 512 MB of RAM
Supported Operating SystemsThe DSC Runtime supports the following operating systems:
[*]Windows 10 (version 1909)
NoteRefer to Unsupported Windows Operating Systems for more information about support for Microsoft Windows OSes.Installation InstructionsNI installs the DSC Runtime using NI Package Manager. If you do not already have NI software installed, the DSC Runtime installs NI Package Manager to handle the installation of your NI software. Visit ni.com/r/NIPMDownload to download NI Package Manager. Refer to the NI Package Manager Manual for more information about installing, removing, and upgrading NI software using NI Package Manager.You can also install LabVIEW and the DSC Runtime by using the LabVIEW Platform media. To request additional LabVIEW Platform media, refer to the NI website.NoteIf you purchased this product with an NI Software Suite or NI Product Bundle, use the installation media that shipped with your purchase to install this product.NoteThe NI OPC Servers application installed with the DSC Runtime provides a temporary license for a two-hour evaluation period. You must activate a valid license to continue using the NI OPC Servers application after the evaluation period expires.SQL Server SupportThe LabVIEW 2021 DSC Module requires Microsoft SQL Server 2012 Service Pack 4 (SP4) Express. This component is installed by default when you install the DSC Module.To install the LabVIEW 2020 DSC Module on a machine that has a previous version of the DSC Module installed, you need to upgrade the Microsoft SQL Server version from 2008 R2 to 2012 SP4 Express. Because upgrading the Microsoft SQL Server affects the Citadel database, you must backup your Citadel data before upgrading. Refer to the Archiving Citadel Data topic in the LabVIEW Help for detailed information about archiving the Citadel database.Product Security and Critical UpdatesVisit ni.com/security to view and subscribe to receive security notifications about NI products. Visit ni.com/r/critical-updates for information about critical updates from NI.Automating the Installation of NI ProductsYou can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.If the NI product you are installing uses Microsoft .NET 4.6.2, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.6.2 separately before you install NI software.For more information about automating the installation of NI products, refer to Automating an Installer in the NI Package Manager manual.Using NI Software with Microsoft Windows 10Microsoft Windows 10 is the latest version of the Windows operating system and features significant changes compared to previous versions. Windows 10 introduces several new capabilities and also combines features from both Windows 7 and Windows 8. For more information about NI support for Windows 10, visit ni.com/windows10.Unsupported Windows Operating SystemsThe Advanced Signal Processing Toolkit no longer supports Windows Vista/XP/7/8.x, Windows Server 2003/2008/2012, or any 32-bit Windows operating system. Versions of this product that ship after May 1, 2021, may not install or execute correctly on these operating systems. For detailed information about NI operating system support, visit https://www.ni.com/r/win32bitsupport.Legal InformationCopyright© 2000–2021 National Instruments Corporation. All rights reserved.Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.NI respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.End-User License Agreements and Third-Party Legal NoticesYou can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
[*]Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories.
[*]EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory.
[*]Review <National Instruments>\_Legal Information.txt for information on including legal information in installers built with NI products.
U.S. Government Restricted RightsIf you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.IVI Foundation Copyright NoticeContent from the IVI specifications reproduced with permission from the IVI Foundation.The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.TrademarksRefer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.PatentsFor patents covering the NI products/technology, refer to the appropriate location: Help» Patents in your software, the patents.txt file on your media, or the NI Patent Notice at ni.com/patents.375311H-01
页:
[1]