石鑫华视觉 发表于 2021-9-7 22:48:31

LabVIEW myRIO Toolkit 2014 Win32Eng LabVIEW 2014myRIO工具包

Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html

视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html

LabVIEW myRIO Toolkit 2014 Win32Eng LabVIEW 2014myRIO工具包

LabVIEW myRIO工具包提供了在myRIO学生嵌入式设备上开发和部署应用程序所需的工具。
LabVIEW myRIO工具包是LabVIEW的软件附件,提供了在myRIO学生嵌入式设备上快速开发和部署应用程序所需的驱动和工具。该工具包为myRIO设备上的每种I/O类型提供了基于配置的Express和Advanced I/O VI,可帮助学生快速构建想法并编写独立的应用程序。

2014myRIO
发布日期
2014/8/4
包含的版本
2014完整版
受支持的操作系统
Windows 8.1
Windows Server 2003 R2 32-bit
Windows XP (SP3) 32-bit
Windows Vista
Windows 8
Windows 7
Windows Server 2008 R2 64-bit
Windows Server 2012 R2 64-bit
应用程序位数
32位
语言
英文
校验和
文件大小: 2654091264 字节 (2.47 GB)
修改日期: 2014-09-30 22:41
MD5: c2d09bc4518e8b53a6320f393da48616(官方正确)
SHA1: becde79c376eca8da57465f144854087f852eeb4
SHA256: 895e94dcb7ff0671278e9ae1f861fc9945ad22a44e89a667e5432058c0c8742b
CRC32: 2136c942

百度网盘与NI官方下载地址:


LabVIEW 2014 myRIO Toolkit ReadmeVersion 14.0.0June 2014This file contains important information about the LabVIEW myRIO Toolkit, including system requirements, installation instructions, new features, known issues, and a partial list of bugs fixed for the LabVIEW 2014 myRIO Toolkit.OverviewSystem RequirementsInstallation InstructionsProduct Security and Critical UpdatesNew FeaturesKnown IssuesBug FixesAccessing the HelpFinding ExamplesAutomating the Installation of NI ProductsHow to Use NI Software with Microsoft Windows 8.xNI Software Support for Microsoft Windows Vista, Windows XP, and Windows Server 2003Legal InformationOverviewThe LabVIEW myRIO Toolkit is a software package that allows you to create and deploy applications on the NI myRIO by using LabVIEW and other National Instruments software.System RequirementsThe myRIO Toolkit has the following requirements:
[*](Optional for C Programming) LabVIEW 2014 Student, Full, or Professional Development System (32-bit)
[*](Optional for C Programming) LabVIEW 2014 Real-Time Module
[*]At least 2 GB of disk space in addition to the LabVIEW-recommended minimum
[*]1 GB RAM
[*]One of the following operating systems for application development:

[*]Windows 8.1 (32-bit and 64-bit)
[*]Windows 8 (32-bit and 64-bit)
[*]Windows 7 (32-bit and 64-bit)
[*]Windows Vista (32-bit and 64-bit)
[*]Windows XP Service Pack 3 Professional
[*]Windows Server 2012 R2 (64-bit)
[*]Windows Server 2003 R2 (32-bit)
[*]Windows Server 2008 R2 (64-bit)

Note:
[*]The myRIO Toolkit is compatible with 32-bit LabVIEW only. Therefore, you must have 32-bit LabVIEW installed even if you use a 64-bit operating system.
[*]You might need more memory than the LabVIEW-recommended minimum depending on the size of the application you design in LabVIEW on the host computer.
[*]Support for Windows Server 2003 R2 may require disabling physical address extensions (PAE). Refer to the National Instruments website for information about how this might affect your use of Windows Server 2003 R2 and what actions you might have to take.
[*]The myRIO Toolkit does not support the Windows Server non-R2 editions.
Refer to the LabVIEW Readme for additional system requirements and supported operating systems for LabVIEW 2014.Installation InstructionsComplete the following steps to install the myRIO Toolkit on a development computer using NI myRIO Software Bundle.
[*]Log in to the development computer as an administrator or as a user with administrative privileges.
[*]Insert NI myRIO Software Bundle DVD 1.
[*]Select Install NI LabVIEW 2014 myRIO Toolkit.
[*](Optional for C Programming) Click the down arrow beside LabVIEW Support and select Install this feature to a local drive.
[*]Click Next and follow the instructions on the screen to install and activate the myRIO Toolkit.
If you download the myRIO Toolkit installer from ni.com/downloads, double-click the setup.exe file in the root directory of the myRIO Toolkit installer and follow the instructions on the screen to install this product.Installing the USBLAN Driver in Microsoft Windows XP and Windows Server 2003You must manually install the USBLAN driver before using NI myRIO with Microsoft Windows XP and Windows Server 2003. Complete the following steps to install the USBLAN driver:
NoteBefore completing the following steps, make sure that you have downloaded and installed the KB 931125 package from Microsoft. For more information, refer to the Workarounds and Recommendations section of KB 65O8AH55, Why Are National Instruments Installers Failing on Windows XP and Server 2003 Machines?.

[*]Connect the NI myRIO to your computer after you install the myRIO Toolkit.
[*]In the Found New Hardware Wizard, select No, not this time and click Next.
[*]Select Install from a list or specific location and click Next.
[*]Select Include this location in the search and navigate to the National Instruments\CompactRIO\Staging\USBLAN\XP directory.
[*]Click Next to install the USBLAN driver. Click Continue Anyway when you see the Windows Logo testing warning.
[*]Click Finish.
The USBLAN device driver now appears under Network adapters in the Windows Device Manager.Product Security and Critical UpdatesVisit ni.com/security to view and subscribe to receive security notifications about National Instruments products. Visit ni.com/critical-updates for information about critical updates from National Instruments.New FeaturesThe LabVIEW 2014 myRIO Toolkit introduces the following new features:Support for Multiple FPGA PersonalitiesThe myRIO Toolkit now supports two FPGA personalities:
[*]Default—Supports general I/O, protocols, and interrupt. Use the default personality for control applications.
[*]High Throughput—Supports high-speed analog or digital data access. Use the high-throughput personality for audio signals and projects in need of waveform data.

NoteBy default, the myRIO Toolkit only includes the default FPGA personality. Visit ni.com/myrio/more to download the high-throughput FPGA personality.
You can choose a personality when you create a myRIO project. With different personalities, you can implement different functionalities. The following table lists the functionalities that default and high-throughput FPGA personalities support.
Supported FunctionalityDefaultHigh Throughput
Analog Input (1 Sample)YesYes
Analog Output (1 Sample)YesYes
Digital InputYesYes
Digital OutputYesYes
ButtonYesYes
LEDYesYes
AccelerometerYesYes
PWMYesNo
EncoderYesNo
SPIYesNo
I2CYesNo
UARTYesYes
InterruptYesNo
Analog Input (N Samples)NoYes
Analog Output (N Samples)NoYes
Audio Input (N Samples)NoYes
Audio Output (N Samples)NoYes
Digital Input (N Samples)NoYes
Digital Output (N Samples)NoYes
Input Device (Joystick)YesYes
Switching between Default and High-Throughput FPGA PersonalitiesThis feature is available only when you install the high-throughput FPGA personality. Visit ni.com/myrio/more to download the high-throughput FPGA personality.To switch between personalities, right-click an NI myRIO target in the Project Explorer window, select Switch FPGA Personality, and choose an available personality from the shortcut menu.
NoteYou cannot switch between personalities in myRIO projects that include customized FPGA code, such as the myRIO Custom FPGA Project.
Refer to the myRIO Toolkit»Creating NI myRIO Applications»Choosing FPGA Personalities topic on the Contents tab of the LabVIEW Help for more information about using the FPGA personalities.Using VIs Compatible with FPGA PersonalitiesThe myRIO palette now consists of the following subpalettes that are compatible with different FPGA personalities:
[*]Default FPGA Personality—Includes VIs that are compatible with the default FPGA Personality.
[*]High Throughput FPGA Personality—Includes VIs that are compatible with the high-throughput FPGA Personality. This subpalette is available only when you install the high-throughput FPGA personality. Visit ni.com/myrio/more to download the high-throughput FPGA personality.

The High Throughput FPGA Personality palette includes Low Level VIs and Express VIs that you can use to acquire and generate analog, audio, and digital signals in the n samples I/O mode. The n samples mode indicates that the NI myRIO acquires and generates multiple samples at the same time for a single channel or multiple channels. Use the n samples mode if you want to acquire finite high frequency signals or to generate finite time-varying signals.
Managing InterruptsThe Interrupt palette includes VIs that you can use to manage analog input, digital input, and timer interrupts on the NI myRIO. An interrupt is a signal indicating an event that needs immediate attention. With the management of interrupts, you can use interrupts to alert an NI myRIO target to a high-priority condition that requires the interruption of the current block diagram code that the NI myRIO target is executing.You can also use the Interrupt Express VI to manage interrupts.Controlling Joystick DevicesThe Input Device Control palette includes VIs that you can use to initialize, query, close, and obtain the state information about the joystick device connected to an NI myRIO.I/O MonitorUse the NI myRIO I/O monitor to test and monitor data from different NI myRIO channels. The NI myRIO I/O monitor supports the following functions:
[*]Acquire or generate analog and digital signals.
[*]Communicate through protocols, including Inter-Integrated Circuit (I2C), Serial Peripheral Interface (SPI), and Universal Asynchronous Receiver/Transmitter (UART).
[*]Generate Pulse Width Modulation (PWM) signals and read values from the encoder.
You can launch the I/O monitor from one of the following places:
[*]In the LabVIEW Getting Started window, click the Set Up and Explore link and select Launch the I/O Monitor.
[*]In the NI myRIO USB Monitor, click Launch the I/O Monitor.
[*]In the Project Explorer window of a myRIO project, right-click a myRIO target and select Launch IO Monitor from the shortcut menu.
Click the Help button in the I/O monitor to access the NI myRIO I/O Monitor Help.Create Network Communication Project WizardYou can use the Create Network Communication Project wizard to create different types of network communication sample projects. Use these sample projects to communicate between a host computer and one or more NI myRIO devices.The following are the sample projects that the Create Network Communication Project wizard can create:
[*]Shared Variable—Demonstrates how to use shared variables to read the latest NI myRIO user button status from a LabVIEW application running on the host computer.
[*]UDP Data Stream—Demonstrates how to use User Datagram Protocol (UDP) to continuously broadcast values from the host computer and receive the values on NI myRIO.
[*]UDP Message—Demonstrates how to use UDP to broadcast messages on demand from the host computer and receive the messages on the NI myRIO.
[*]Network Stream—Demonstrates how to use network streams to continuously stream values from a LabVIEW application running on the host computer to the NI myRIO.
[*]Network Stream Message—Demonstrates how to use network streams to transmit messages from a LabVIEW application running on the host computer to the NI myRIO.
[*]TCP Data Stream—Demonstrates how to use Transmission Control Protocol (TCP) to continuously stream values from the host computer to the NI myRIO.
[*]TCP Message—Demonstrates how to use TCP to transmit messages from the host computer to one or more NI myRIOs.
[*]Simple TCP Messaging—Demonstrates how to use TCP and meta data to transmit messages from the host computer to the NI myRIO.
[*]Queued Message—Demonstrates how to use a queued message handler to transmit messages from the host computer to the NI myRIO.
Complete the following steps to launch the Create Network Communication Sample Project wizard:
[*]Launch LabVIEW.
[*]Select File»Create Project to launch the Create Project dialog box.
[*]Select Sample Projects»myRIO to filter the Project List.
[*]Select Network Communication (myRIO) from the myRIO sample project list.
[*]Click Finish to launch the Create Network Communication Project wizard.
Miscellaneous Palette and VI Changes
[*]The Advance I/O palette is renamed the Low Level palette.
[*]The Utilities palette is renamed the Device Management palette.
[*]The Onboard and the Onboard Devices Express palettes no longer exist. VIs used to reside on these palettes now reside on both the Default FPGA Personality palette and the High Throughput FPGA Personality palette.
[*]The Analog Input, Analog Output, Digital Input, and Digital Output Express VIs include the following new options:

[*]I/O mode—Specifies the I/O mode this Express VI uses.
[*]Sample rate—Specifies the sampling frequency of the input or output signal.
[*]Samples—Specifies the number of samples you want to read or write.
[*]Latency—Displays the latency between two adjacent signal acquisition or generation iterations.

Known IssuesYou can access the software and documentation known issues list online. Refer to the National Instruments website for an up-to-date list of known issues in the LabVIEW myRIO Toolkit.Bug FixesThe following items are the IDs and titles of a subset of issues fixed in the LabVIEW myRIO Toolkit.
IDFixed Issue
424379Unable to reset the NI myRIO when UART has been used
426237The Write VI neither returns data nor returns an error when you use this VI to write an unconfigured I2C channel
428301The UART Express VI enables termination characters by default
Accessing the HelpRefer to the LabVIEW Help, accessible by selecting Help»LabVIEW Help from LabVIEW, for information about the myRIO Toolkit.Finding ExamplesSelect Help»Find Examples from LabVIEW to launch the NI Example Finder. LabVIEW examples for the myRIO Toolkit are located in the labview\examples\myRIO directory. You can modify an example VI to fit an application, or you can copy and paste from one or more examples into a VI that you create.Automating the Installation of NI ProductsYou can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes. However, starting with the August 2012 releases (products using NI Installers version 3.1 or later), you may need to perform additional steps before or during a silent installation of NI software.If the NI product you are installing uses Microsoft .NET 4.0, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.0 separately before you install NI software.For more information about automating the installation of NI products, refer to the following KnowledgeBase articles:
[*]For more information about silent installations of individual NI products, refer to KB 4CJDP38M, Automating the Installation of a Single Installer.
[*]For more information about silent installations of NI products in a suite, such as NI Developer Suite, refer to KB 4GGGDQH0, Automating the Installation of a Suited Installer.
[*]To determine what version of NI Installers your product contains, refer to KB 4CJDR18M, How Can I Determine the Type and Version of My National Instruments Installer?.
How to Use NI Software with Microsoft Windows 8.xWhen you install National Instruments software on Microsoft Windows 8.x, you will notice a few additional tiles in the Apps view, including shortcuts to NI application software products such as NI LabVIEW, Measurement & Automation Explorer (NI MAX), and NI Launcher.Using NI LauncherNI Launcher helps you find and launch installed NI products. It provides you with a method of finding NI products similar to the Start menu in previous versions of Microsoft Windows. To use NI Launcher, click the NI Launcher tile in the Apps view. NI Launcher launches the desktop and opens a menu containing a list of NI products. Click any NI product to launch it.
NoteNI MAX does not appear as a desktop shortcut when installed on Microsoft Windows 8.x. You can launch NI MAX either from the Apps view or from within NI Launcher.
Pinning Frequently Used ApplicationsFor convenience, you can pin your most-used NI applications, such as MAX, to either the Start screen or the Taskbar on the desktop, as necessary:
Current ApplicationIcon LocationPin to Action
Windows 8.x DesktopDesktop TaskbarRight-click application and select Pin to Taskbar
Windows 8.x DesktopStart screenRight-click application and select Pin to Start
Windows 8.x Start screenDesktop TaskbarRight-click application and select Pin to taskbar from the menu bar on the bottom of the screen
Finding All ProgramsIf you want to find a particular application or related files, such as documentation files, from the Start screen, you can access all installed files from the Apps view. To get to the Apps view, right-click anywhere on the Start screen and select All apps (Windows 8) or click the down arrow on the bottom left of the screen (Windows 8.1).For more information about NI support for Windows 8.x, visit ni.com/windows8.NI LabVIEW myRIO Toolkit Drops Support for Microsoft Windows Vista, Windows XP, and Windows Server 2003 in 2016National Instruments LabVIEW myRIO Toolkit will drop support for Microsoft Windows Vista, Windows XP, and Windows Server 2003 as of July 1, 2016. Versions of LabVIEW myRIO Toolkit that ship after July 1, 2016 will not install or run on Windows Vista, Windows XP, or Windows Server 2003. For detailed information about NI application software product life cycles, visit ni.com/info and enter one of the following Info Codes:
ProductInfo Code
NI LabVIEWlifecycle
NI LabWindows™/CVI™cvi_lifecycle
NI Measurement Studiomstudiolifecycle
NI TestStandtslcp
NI DIAdemddlcp
NI SignalExpressselcp
NI VeriStandnivslifecycle
Legal InformationCopyright© 2013–2014 National Instruments. All rights reserved.Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.End-User License Agreements and Third-Party Legal NoticesYou can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
[*]Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories.
[*]EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory.
[*]Review <National Instruments>\_Legal Information.txt for information on including legal information in installers built with NI products.
U.S. Government Restricted RightsIf you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 for military agencies.IVI Foundation Copyright NoticeContent from the IVI specifications reproduced with permission from the IVI Foundation.The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.TrademarksRefer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.PatentsFor patents covering the National Instruments products/technology, refer to the appropriate location: Help» Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.
页: [1]
查看完整版本: LabVIEW myRIO Toolkit 2014 Win32Eng LabVIEW 2014myRIO工具包

LabVIEW HALCON图像处理入门教程(24.09)
石鑫华机器视觉与LabVIEW Vision图像处理PDF+视频教程11种全套
《LabVIEW Vision函数实例详解2020-2024》教程-NI Vision所有函数使用方法介绍,基于NI VISION2020,兼容VDM21/22/23/24