NI RFmx Waveform Creator 19.0 Full Win32/64ENG RFmx波形创造器19.0完整版
Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html
NI RFmx Waveform Creator 19.0 Full Win32/64ENG RFmx波形创造器19.0完整版
RFmx Waveform Creator
RFmx Waveform Creator可帮您创建、可视化和再现通用型、蜂窝、连接性、物联网(IoT)、航空航天/防卫测试应用程序的波形。
RFmx Waveform Creator是一款应用软件,您可以用来创建通用的和基于标准的波形,用于设计、验证和生产测试应用。借助这款软件,您可以结合信号发生器以交互方式生成波形,或保存开放的、未锁定的波形文件,用于借助自动仪器进行回放或仿真波形。该软件内置有标准的信号配置;您也可以修改、保存和加载自己的自定义波形参数。此外,在预览时域、频域和功率域的信号特征之前,您可以使用RFmx Waveform Creator来应用信号减损、滤波、波峰因子降低(CFR)等功能。
发布日期:
2019/6/27
包含的版本:
19.0完整版
受支持的操作系统:
Windows Server 2008 R2 64-bit
Windows 7 (SP1) 64-bit
Windows 8.1 64-bit
Windows 10 64-bit
Windows Server 2012 R2 64-bit
语言:
英文
应用程序位数:
32/64位
校验和:
文件大小: 681158656 字节 (649.60 MB)
修改日期: 2019-08-07 15:40
MD5: 1941e653965d09c7495a1478153ba3ed
SHA1: 56847b08d583962d9e73719353d7e626a2667379
SHA256: df4954fcbf170dd0f9524dad8df7edd2cedd39e1334957d1482b69626fd42a4b
CRC32: efbd4475
百度网盘和NI官方下载地址:
注册登录视觉论坛用户,购买附件查看下载地址
RFmx Waveform Creator 19.0 ReadmeJune 2019This file contains important information about RFmx Waveform Creator, including installation instructions, new features, bugs fixes, and known issues.OverviewNew FeaturesSupported HardwareSystem RequirementsSupported Operating SystemsInstallation InstructionsInstalled SoftwareFile LocationsExecutableFinding ExamplesAccessing the DocumentationProduct Security and Critical UpdatesBehavior ChangesKnown IssuesBug FixesAutomating the Installation of NI ProductsUsing NI Software with Microsoft Windows 10Using NI Software with Microsoft Windows 8.1RFmx Waveform Creator Drops Support for Windows 7 (64-Bit) and Windows Server 2008 R2 in 2021Legal InformationOverviewRFmx Waveform Creator provides a unified interface for creating and generating waveforms for multiple wireless standards. You can create unencrypted, unlocked IQ waveform files for playback on NI PXI RF instrumentation.Supported standards include LTE/LTE-Advanced, W-CDMA/HSPA+, GSM/EDGE+, TD-SCDMA, and more.New FeaturesRFmx Waveform Creator 19.0 includes the following new features:
[*]Support for PXIe-5830 (EAP) and PXIe-5831 (EAP)
[*]Support for Cat-M2 Uplink (Release 14) and Cat-NB2 Uplink in LTE modulation scheme
[*]5G new radio (NR) modulation scheme
[*]Added support for Uplink Pi/2 BPSK Spectral Shaping
[*]Support for downlink test models as defined in 3GPP TS 38.141-1 and 3GPP TS 38.141-2 (Change requests R4-1905121, R4-1905122 endorsed in April 2019, to be updated in v15.2.0 when it releases in June 2019)
[*]Support for Resume Waveform Playback in Download and Play window
RFmx Waveform Creator 3.0 includes the following new features:
[*]Addition of 5G new radio (NR) modulation scheme
[*]Support for launching the WLAN Generation SFP
[*]Support for launching the Bluetooth Generation SFP
[*]Support for PXIe-5820
[*]Addition of crest factor reduction (CFR) in LTE, NR, and Multi-Carrier modulation schemes. Supported CFR types are Clipping and Peak Windowing.
[*]Support for custom output sample rate in multi-carrier plugin.
[*]GSM relative power per slot
RFmx Waveform Creator 2.5 includes the following new features:
[*]Support for waveform generation in eMTC uplink features such as,
[*]
[*]Frequency Hopping
[*]Guard symbols
[*]Support for waveform generation in NB-IoT uplink features such as,
[*]
[*]Single/multi tones
[*]15kHz/3.75kHz subcarrier spacing
[*]NPUSCH Format 1/2
[*]Support for LTE-LAA Resource Allocation Type 3
[*]Support for 64-bit
[*]Addition of the Waveform Summary window
[*]Support for multi-carrier generation utility
[*]Support for generating tones up to 1.25G
[*]Support for updating the window duration based on LTE bandwidth
[*]Improvements in the performance of waveform generation
Supported HardwareVector Signal Generators
[*]PXIe-5673
[*]PXIe-5673E
Device-specific information about these modules is included in the NI RF Vector Signal Generators Help.Vector Signal Transceivers
[*]PXIe-5644
[*]PXIe-5645
[*]PXIe-5646
[*]PXIe-5840
[*]PXIe-5820
[*]PXIe-5830 (EAP)
[*]PXIe-5831 (EAP)
Device-specific information about these modules is included in the NI RF Vector Signal Transceivers Help.System RequirementsRFmx Waveform Creator has the following requirements:
[*]Processor—1 GHz 64-bit (x64) processor
[*]4 GB RAM*
[*]A screen resolution of 1,024 x 768
[*]Windows 10/8.1/7, with all available critical updates and service packs
*Depending on the amount of data acquired and/or processed, a larger amount of memory may be required.Supported Operating SystemsRFmx Waveform Creator 19.0 supports the following 64-bit operating systems:
[*]Windows 10/8.11/7 SP12
[*]Windows Server 2012 R21
[*]Windows Server 2008 R2 SP12
1 NI software installs VC2015 Runtime and .NET 4.6.2. Windows 8.1 and Windows Server 2012 R2 require Microsoft updates to support these items. Refer to Microsoft KB2919442 and KB2919355 for more information about how to install these updates.2 NI software is signed with a SHA-256 certificate. Windows 7 SP1 and Windows Server 2008 R2 SP1 require Microsoft updates to support SHA-256. Refer to Microsoft KB3033929 for more information about how to install this security update.NoteIn 2019, RFmx Waveform Creator dropped support for all 32-bit Windows operating systems. RFmx Waveform Creator will not install or run on an unsupported OS. Refer to RFmx Waveform Creator Drops Support for Windows 7 (64-Bit) and Windows Server 2008 R2 in 2021 for information about future OS support.Other Required Software
[*]NI-RFSG 14.5 or later
Installation InstructionsNI installs RFmx Waveform Creator using NI Package Manager. If you do not already have NI software installed, RFmx Waveform Creator installs NI Package Manager to handle the installation of your NI software. Visit ni.com/info and enter the Info Code NIPMDownload to download NI Package Manager. Refer to the NI Package Manager Manual for more information about installing, removing, and upgrading NI software using NI Package Manager.Installed SoftwareInstalled Software
[*]<NIDocDir> is an alias for the following National Instruments file folder location: Users\Public\Public Documents\National Instruments
[*]<MSTUDIOVS2010DIR> is an alias for the following National Instruments file folder location:
[*]Program Files (x86)\National Instruments\MeasurementStudioVS2010
[*]<NIDir> is an alias for the following National Instruments file folder location:
[*] Program Files (x86)\National Instruments
[*]<SYSDIR> is an alias for the following file folder location:
[*]Windows\SysWOW64 for 32-bit programs and windows\system32 for 64-bit programs
File Locations
ItemInstalled Location
DLLs<NIDir>
Examples<NIDir>\examples
ExecutableSelect Start»All Programs»National Instruments»RFmx Waveform Creator»RFmx Waveform Creator Examples to launch the RFmx Waveform Creator.Finding ExamplesYou can access all the installed RFmx Waveform Creator examples at Start»All Programs»National Instruments»RFmx Waveform Creator»RFmx Waveform Creator Examples.Accessing the DocumentationDocumentation for RFmx Waveform Creator is located at Start»All Programs»National Instruments»RFmx Waveform Creator»RFmx Waveform Creator Documentation. The documentation set is composed of the following documents.
DocumentFormatDescription
RFmx Waveform Creator HelpHTML/Windows HelpInformation about the RFmx Waveform Creator. This help file is an HTML version of a traditional user manual that includes the following information:
[*]An introduction to RFmx Waveform Creator
[*]How to get started with the application
[*]A complete reference of all the different modulation schemes supported
RFmx Waveform Creator 19.0 ReadmeHTML (this document)Information about supported hardware and operating systems, new features, fixed issues, and legal notices.
For the most recent revisions of documentation and for newly released documentation, visit ni.com/manuals.Product Security and Critical UpdatesVisit ni.com/security to view and subscribe to receive security notifications about National Instruments products. Visit ni.com/critical-updates for information about critical updates from National Instruments.Behavior ChangesThe following items are the behavior changes in RFmx Waveform Creator 19.0 from RFmx Waveform Creator 3.0.
[*]5G new radio (NR) modulation scheme
[*]Deprecated support for Slot Offset control
[*]Default value of downlink Channel Configuration Mode control has changed to Test Model from User defined.
[*]Default value of BWP Number of RBs control has changed to -1 from maximum number of resource blocks.
[*]Added SSB Active Blocks control and deprecated SSB Transmitted Pattern control under SS/PBCH Block configurations window.
[*]Saving of waveforms in evaluation mode is not allowed in WLAN and Bluetooth
The following items are the behavior changes in RFmx Waveform Creator 3.0 from RFmx Waveform Creator 2.5.
[*]Fractional resampling is performed in LTE and NR carrier aggregation so that the final sample rate is a multiple of 3.84 MHz.
[*]CCDF graph calculates PAPR based on generated waveform excluding OFF power period.
[*]UI controls on the Download & Play window are reset based on selected device.
The following items are the behavior changes in RFmx Waveform Creator 2.5 from RFmx Waveform Creator 2.4.
[*]Updated the PAPR calculation for bursty signals in the presence of noise.
[*]Removed restriction on configuring resource allocation type 0 and resource allocation type 1 settings in LTE.
Known IssuesThe following item is a known issue in RFmx Waveform Creator 19.0.
IDKnown Issue
711673PAPR displayed on CCDF graph does not match with PAPR stored in the tdms file in User plugin.
736118When Waveform Creator aggregates multiple carriers, it may adjust the carrier offsets to ensure resultant signal is phase continuous. To avoid coercions of the carrier offsets, set offsets to be an integer multiple of (1/signal duration). In case you are setting NR spacing type to Nominal, set Reference CC Index to a valid CC Index, instead of -1.
Bug FixesThe following items are the IDs and titles of a subset of issues fixed in RFmx Waveform Creator. This is not an exhaustive list of issues fixed in the current version of the RFmx Waveform Creator. If you have a CAR ID, you can search this list to validate that the issue has been fixed.The following items are changes in RFmx Waveform Creator 19.0 from RFmx Waveform Creator 3.0
IDFixed Issue
734588Fixed an issue where the error message was getting cleared in Download and Play window when switching between windows
732228Fixed an issue where the speed degradation in CFR operations for waveform size was less than 20M samples.
724892Fixed an issue where the Graphics tab IQ FFT view was not scaling correctly in corner case when the bandwidth was increased.
695883Fixed the issue of WFC precision being low, 14 bits.
The following items are changes in RFmx Waveform Creator 3.0 from RFmx Waveform Creator 2.5
IDFixed Issue
704721Fixed the phase discontinuity issue on configuring GSM on first slot and EDGE on last slot.
698120Fixed the issue where CCDF graph was reporting negative results for some configurations.
701478Fixed the issue of not reporting burst start and stop locations for NB-IoT and eMTC FDD.
705738 and 701490Fixed the issue of reporting incorrect burst PAPR for impaired bursty signal in Multi-Carrier and User plugins.
712524Fixed the issue where IQ impairments per carrier set were incorrect, when multiple carrier sets are configured.
The following items are changes in RFmx Waveform Creator 2.5 from RFmx Waveform Creator 2.4
IDFixed Issue
685187Fixed issue where an overflow error was reported on generating LTE.
700390Fixed issue where the PAPR calculation for bursty signals with user plugin was incorrect.
Automating the Installation of NI ProductsYou can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes.If the NI product you are installing uses Microsoft .NET 4.0, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.0 separately before you install NI software.For more information about automating the installation of NI products, refer to the following KnowledgeBase articles:
[*]For more information about silent installations of individual NI products, refer to Customize and Automate Installation of a Single Installer.
[*]For more information about silent installations of NI products in a suite, such as NI Developer Suite, refer to Customize and Automate Installation of a Suited Installer.
[*]To determine what version of NI Installers your product contains, refer to Determine Type and Version of My National Instruments Installer.
Using NI Software with Microsoft Windows 10Microsoft Windows 10 is the latest version of the Windows operating system and features significant changes compared to previous versions. Windows 10 introduces several new capabilities and also combines features from both Windows 7 and Windows 8. For more information about NI support for Windows 10, visit ni.com/windows10.Using NI Software with Microsoft Windows 8.1When you install NI software on Microsoft Windows 8.1, you will notice a few additional tiles in the Apps view, including shortcuts to NI application software products such as NI LabVIEW, Measurement & Automation Explorer (NI MAX), and NI Launcher. For more information about NI support for Windows 8.1, visit ni.com/windows8.RFmx Waveform Creator Drops Support for Windows 7 (64-Bit) and Windows Server 2008 R2 in 2021RFmx Waveform Creator will drop support for Windows 7 (64-bit) and Windows Server 2008 R2 starting in 2021. Versions of this product that ship after May 1, 2021, may not install or execute correctly on these operating systems. For detailed information about NI operating system support, visit ni.com/r/win32bitsupport.For detailed information about NI application software product life cycles, visit ni.com/info and enter one of the following Info Codes:
ProductInfo Code
LabVIEWlifecycle
LabWindows/CVIcvi_lifecycle
Measurement Studiomstudiolifecycle
TestStandtslcp
DIAdemddlcp
SignalExpressselcp
VeriStandnivslifecycle
Legal InformationCopyright© 2017–2019 National Instruments. All rights reserved.Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.NI respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.End-User License Agreements and Third-Party Legal NoticesYou can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
[*]Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories.
[*]EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory.
[*]Review <National Instruments>\_Legal Information.txt for information on including legal information in installers built with NI products.
U.S. Government Restricted RightsIf you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.IVI Foundation Copyright NoticeContent from the IVI specifications reproduced with permission from the IVI Foundation.The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.TrademarksRefer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.PatentsFor patents covering the NI products/technology, refer to the appropriate location: Help» Patents in your software, the patents.txt file on your media, or the NI Patent Notice at ni.com/patents.
377066F-01
页:
[1]