NI RFmx W-CDMA/HSPA+ 2.0 Full Win32/64ENG RFmx W-CDMA/HSPA/HSPA+蜂窝测试2.0完整版
Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html
NI RFmx W-CDMA/HSPA+ 2.0 Full Win32/64ENG RFmx W-CDMA/HSPA/HSPA+蜂窝测试2.0完整版
RFmx W-CDMA/HSPA+
RFmx W-CDMA/HSPA+为W-CDMA、HSPA和HSPA+蜂窝测试应用提供信号生成和分析功能。
RFmx W-CDMA/HSPA+是一款测量专用软件,旨在扩展NI RF仪器生成和分析W-CDMA、HSPA和HSPA+蜂窝信号的能力。该软件可以通过误差矢量幅度(EVM)、码域误差(CDE)、相邻信道泄漏比(ACLR)、频谱发射屏蔽(SEM)等符合标准的物理层测量,对W-CDMA、HSUPA和HSUPA+上行链路信号进行分析。借助RFmx,您可通过交互式软面板快速轻松地执行和调试测量,使用RFmx Waveform Creator创建和回放开放的未锁定波形,并结合更高性能的API加快自动化测试的速度。
发布日期:
2015/10/17
包含的版本:
2.0完整版
受支持的操作系统:
Windows 10
Windows 8.1
Windows 7
Windows Server 2008 R2 64-bit
语言:
英文
应用程序位数:
32/64位
校验和:
文件大小: 680518432 字节 (648.99 MB)
修改日期: 2015-10-17 06:15
MD5: a122f34fff71256dcfd7c2bc1d387867
SHA1: 052a0491cd6f9a6827cce6fbfe0a88c6227b1017
SHA256: 5de3fb2d1dc0049f2d32ff21798ba57f98149e0af042660dead5bc7130eeef5b
CRC32: 159a2cd5
百度网盘和NI官方下载地址:
注册登录视觉论坛用户,购买附件查看下载地址
NI-RFmx WCDMA 2.0 ReadmeOctober 2015Thank you for using NI-RFmx WCDMA. This file contains important information about NI-RFmx WCDMA and is organized into the following sections:Installation InstructionsSupported HardwareSystem RequirementsInstalled Software, Documentation, and ExamplesExecutableDocumentationAccessing VIs and FunctionsFinding ExamplesProduct Security and Critical UpdatesUninstalling/Modifying NI-RFmx WCDMAKnown IssuesIncreasing Available Memory For Your ApplicationAutomating the Installation of NI ProductsUsing NI Software with Microsoft Windows 10Using NI Software with Microsoft Windows 8.xLegal InformationInstallation InstructionsCautionBefore you install NI-RFmx WCDMA 2.0, ensure that you have uninstalled all related NI-RFmx 1.0 products.
NI-RFmx drivers require that all the installed drivers have the same version for proper functionality. This requirement is because the NI-RFmx drivers share components. If driver incompatibilities exist, they are reported through a dialog box after installation. You can also use the Version Compatibility Checker utility to manually check for version incompatibilities. Refer to the Installed Software, Documentation, and Examples section for more information about the installed location of the Version Compatibility Checker utility.Supported HardwareVector Signal Analyzers
[*]NI PXIe-5663
[*]NI PXIe-5663E
[*]NI PXIe-5665
[*]NI PXIe-5668R
Device-specific information about these modules is included in the NI RF Vector Signal Analyzers Help.Vector Signal Transceivers
[*]NI PXIe-5644R
[*]NI PXIe-5645R
[*]NI PXIe-5646R
Device-specific information about these modules is included in the NI RF Vector Signal Transceivers Help.System RequirementsSupported Operating SystemsNI-RFmx WCDMA 2.0 supports the following operating systems:
[*]Windows 10 (32-bit and 64-bit)
[*]Windows 8.1 (32-bit and 64-bit)
[*]Windows 8.0 (32-bit and 64-bit)
[*]Windows 7 (32-bit and 64-bit)
[*]Windows Server 2008 R2 (64-bit)
NoteNI-RFmx WCDMA 2.0 does not support Windows Server non-R2 editions.NI recommends that you have the most recent service pack for your operating system installed.Minimum System Requirements
[*]Processor—Intel i3 or equivalent
[*]RAM—2 GB*
[*]Microsoft Internet Explorer 5.5 or later
[*]A screen resolution of 1,300 x 700 with 256 colors
[*]Windows 10/8.1/8.0/7, with all available critical updates and service packs
*Depending on the amount of data acquired and/or processed, a larger amount of memory may be required.Recommended System
[*]Processor—Intel i5 or equivalent
[*]RAM—4 GB*
[*]Microsoft Internet Explorer 5.5 or later
[*]A screen resolution of 1,300 x 700
[*]Windows 10/8.1/8.0/7, with all available critical updates and service packs
*Depending on the amount of data acquired and/or processed, a larger amount of memory may be required.
Application Development Environments (ADEs)
[*]NI LabVIEW 2013 SP1 (32-bit and 64-bit) f6 patch, 2014 SP1 (32-bit and 64-bit) f3 patch, 2015 (32-bit and 64-bit) f1 patch
NoteNI-RFmx WCDMA does not operate correctly without the NI LabVIEW service packs and patches in the preceding list.NoteInstall NI LabVIEW before you install NI-RFmx WCDMA. To add support for ADEs that are installed after you install NI-RFmx WCDMA, modify your NI-RFmx WCDMA installation or relaunch the NI-RFmx WCDMA installer.Other Required Software
[*]NI-RFSA 14.1 or later
Installed Software, Documentation, and Examples
[*]<NIDir> is an alias for the following National Instruments file folder location:
[*]Windows 10 (32-bit)/8.1 (32-bit)/8.0 (32-bit)/7 (32-bit): Program Files\National Instruments
[*]Windows 10 (64-bit)/8.1 (64-bit)/8.0 (64-bit) /7 (64-bit): Program Files (x86)\National Instruments
[*]<SYSDIR> is an alias for the following file folder location:
[*]Windows 10 (32-bit)/8.1 (32-bit)/8.0 (32-bit)/7 (32-bit): windows\system32
[*]Windows 10 (64-bit)/8.1 (64-bit)/8.0 (64-bit) /7 (64-bit)
[*]32-bit DLL: windows\SysWow64
[*]64-bit DLL: windows\system32
File Locations
ItemInstalled Location on Windows 10/8.1/8.0/7
Version Compatibility Checker<NIDir>\RFmx\niRFmxCompatibility_Checker.exe
DLLs<SYSDIR>
LabVIEW Examples<NIDir>\LabVIEW <version>\examples\RFmx\WCDMA
ExecutableSelect Start»All Programs»National Instruments»NI-RFmx WCDMA»NI-RFmx WCDMA Measurement Interactive Panel to launch the NI-RFmx WCDMA Measurement Interactive Panel.DocumentationDocumentation for NI-RFmx WCDMA is located at Start»All Programs»National Instruments»NI-RFmx WCDMA»RFmx WCDMA Documentation. The documentation set is composed of the following documents.
DocumentFormatDescription
NI-RFmx WCDMA HelpHTML/Windows HelpInformation about NI-RFmx WCDMA. This help file is an HTML version of a traditional user manual that includes the following information:
[*]An introduction to NI-RFmx WCDMA
[*]How to get started with application development
[*]A complete reference for all NI-RFmx WCDMA programming VIs
NI-RFmx WCDMA 2.0 ReadmeHTML (this document)Information about supported hardware, operating systems, and legal notices.
For the most recent revisions of documentation and for newly released documentation, visit ni.com/manuals.Accessing VIs and FunctionsNI-RFmx WCDMA palette VIs are available from the Functions»Measurement I/O»NI-RFmx»WCDMA palette.Finding ExamplesYou can access all the installed NI-RFmx WCDMA examples at Start»All Programs»National Instruments»NI-RFmx WCDMA»RFmx WCDMA Examples.Product Security and Critical UpdatesVisit ni.com/security to view and subscribe to receive security notifications about National Instruments products. Visit ni.com/critical-updates for information about critical updates from National Instruments.Uninstalling/Modifying NI-RFmx WCDMAFor Windows 7, complete the following steps:
[*]Launch the Control Panel by selecting Start»Control Panel.
[*]Double-click Programs and Features.
[*]Select National Instruments Software.
[*]Click the Uninstall/Change button.
[*]Select NI-RFmx WCDMA 2.0 from the dialog box that appears.
[*]Click Remove to uninstall the product; click Modify to change the components that are installed.
For Windows 10/8.1/8.0, complete the following steps:
[*]Right-click on the Start screen.
[*]Select All apps, and launch the Control Panel.
[*]Select Programs» Programs and Features.
[*]Select National Instruments Software.
[*]Click the Uninstall button.
[*]Select NI-RFmx WCDMA 2.0 from the dialog box that appears.
[*]Click Remove to uninstall the product; click Modify to change the components that are installed.
As part of the NI-RFmx WCDMA 2.0 installation, the following software is installed. To completely remove the NI-RFmx WCDMA 2.0 installation from your system, you must also remove the following package:
[*]NI-RFmx WCDMA Runtime 2.0 for LabVIEW
NoteDo not attempt to uninstall by manually deleting files.Known IssuesYou can access the software and documentation known issues list online. Refer to the NI-RFmx WCDMA 2.0 Known Issues at ni.com for an up-to-date list of known issues in NI-RFmx WCDMA 2.0.Increasing Available Memory For Your ApplicationWhen developing memory intensive applications, you may encounter memory limits because 32-bit Windows applications utilize only 2 GB of memory by default. To expand the amount of memory an application can utilize, you can configure the executable to be large address aware to gain access to up to 3 GB of memory on a 32-bit Windows operating system and up to 4 GB of memory on a 64-bit Windows operating system.For more information, refer to Memory Limits for Windows and Windows Server Releases on the Microsoft website.
NoteLabVIEW 8.5 and later are large address aware. For more information, refer to KB 2HDEH9DT How Much Memory can LabVIEW 32-bit or 64-bit Use?.
In TestStand 2013 and later, the Large Address Aware flag is enabled by default for the TestStand Sequence Editor and TestStand User Interfaces. For more information, refer to KB 5ZREUK2G Using the Large Address Aware Flag With TestStand Applications.Automating the Installation of NI ProductsYou can automate the installation of most NI products using command-line arguments to suppress some or all of the installer user interface and dialog boxes. However, starting with the August 2012 releases (products using NI Installers version 3.1 or later), you may need to perform additional steps before or during a silent installation of NI software.If the NI product you are installing uses Microsoft .NET 4.0, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.0 separately before you install NI software.For more information about automating the installation of NI products, refer to the following KnowledgeBase articles:
[*]For more information about silent installations of individual NI products, refer to KB 4CJDP38M, Automating the Installation of a Single Installer.
[*]For more information about silent installations of NI products in a suite, such as NI Developer Suite, refer to KB 4GGGDQH0, Automating the Installation of a Suited Installer.
[*]To determine what version of NI Installers your product contains, refer to KB 4CJDR18M, How Can I Determine the Type and Version of My National Instruments Installer?.
Using NI Software with Microsoft Windows 10Microsoft Windows 10 is the latest version of the Windows operating system and features significant changes compared to previous versions. Windows 10 introduces several new capabilities and also combines features from both Windows 7 and Windows 8. For more information about NI support for Windows 10, visit ni.com/windows10.Using NI Software with Microsoft Windows 8.xWhen you install National Instruments software on Microsoft Windows 8.x, you will notice a few additional tiles in the Apps view, including shortcuts to NI application software products such as NI LabVIEW, Measurement & Automation Explorer (NI MAX), and NI Launcher.Using NI LauncherNI Launcher helps you find and launch installed NI products. It provides you with a method of finding NI products similar to the Start menu in previous versions of Microsoft Windows. To use NI Launcher, click the NI Launcher tile in the Apps view. NI Launcher launches the desktop and opens a menu containing a list of NI products. Click any NI product to launch it.
NoteNI MAX does not appear as a desktop shortcut when installed on Microsoft Windows 8.x. You can launch NI MAX either from the Apps view or from within NI Launcher.
Pinning Frequently Used ApplicationsFor convenience, you can pin your most-used NI applications, such as MAX, to either the Start screen or the Taskbar on the desktop, as necessary.
Current ApplicationIcon LocationPin to Action
Windows 8.x DesktopDesktop TaskbarRight-click application and select Pin to Taskbar
Windows 8.x DesktopStart screenRight-click application and select Pin to Start
Windows 8.x Start screenDesktop TaskbarRight-click application and select Pin to taskbar from the menu bar on the bottom of the screen
Finding All ProgramsIf you want to find a particular application or related files, such as documentation files, from the Start screen, you can access all installed files from the Apps view. To get to the Apps view, right-click anywhere on the Start screen and select All apps (Windows 8) or click the down arrow on the bottom left of the screen (Windows 8.1).For more information about NI support for Windows 8.x, visit ni.com/windows8.Legal InformationCopyright© 2015 National Instruments. All rights reserved.Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.End-User License Agreements and Third-Party Legal NoticesYou can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
[*]Notices are located in the <National Instruments>\_Legal Information and <National Instruments> directories.
[*]EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory.
[*]Review <National Instruments>\_Legal Information.txt for information on including legal information in installers built with NI products.
U.S. Government Restricted RightsIf you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.IVI Foundation Copyright NoticeContent from the IVI specifications reproduced with permission from the IVI Foundation.The IVI Foundation and its member companies make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. The IVI Foundation and its member companies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.TrademarksRefer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.PatentsFor patents covering the National Instruments products/technology, refer to the appropriate location: Help» Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.375559A-01
页:
[1]