NI LabVIEW 2015 Win64ENG 64位LV2015英文版下载
Windows系统下(Linux和MAC系统下请自行了解清楚)NI的各种软件、模块、工具包、驱动程序,使用NI许可证管理器来激活的,绝大部分的都可以使用NI Lincense Activator来激活:NI序列号Serial Number生成激活工具NI License Activator,LabVIEW/VBAI/VDM/VAS等软件模块工具包破解工具不限版本http://visionbbs.com/thread-490-1-1.html视觉论坛的各种NI资源,除了视觉相关的模块有使用外,大部分的都不会使用,仅提供资源不提供技术支持。资源的下载地址一般会同时提供NI官方和百度网盘的地址。某些工具包NI地址失效或没有NI地址,只能使用百度网盘地址;如果百度网盘地址失效过期,可联系论坛客服更新。NI的服务器在美国,有时候速度很慢或下载容易出错,这样会造成安装时各种错误而无法安装。建议在下载完成后,对下载资源做校验和(NI一般会提供MD5或SHA256等)验证,与官方或视觉论坛提供的校验和对比,一致就可以安装;如不一致,则需要重新下载。视觉论坛早期下载上传的资源,基本上都是正常下载的资源;2019后下载的资源,都与NI的正确校验和对比过,保证是正确的资源才上传到百度网盘。校验和工具下载地址:文件Hash计算器FHash,文件校验和验证下载文件正确性验证,MD5值计算、SHA1值计算、SHA256值计算、CRC32值计算http://visionbbs.com/thread-26524-1-1.html
NI LabVIEW 2015 Win64ENG 64位LV2015英文版下载
百度网盘下载:
标准下载:
链接: 请注册视觉论坛会员登录后购买附件下载查看
提取码: 请购买附件下载查看
下载器下载:
链接: 请注册视觉论坛会员登录后购买附件下载查看
提取码: 请购买附件下载查看
NI官方下载地址(可能无效或无法下载完成):
标准下载(EXE版和ZIP版内容一样,EXE为早年发行版,ZIP为后期重新压制版):
请购买附件下载查看
NI下载器下载:
请购买附件下载查看
LabVIEW 2015 Readme for WindowsJune 2015
Refer to the National Instruments website for the latest information about LabVIEW 2015.
System RequirementsProduct Security and Critical UpdatesLabVIEW 2015 (64-bit)Bug FixesFinding ExamplesHow to Use NI Software with Microsoft Windows 8.xLegal InformationSystem Requirements
WindowsRun-Time EngineDevelopment Environment
ProcessorPentium III/Celeron 866 MHz (or equivalent) or later (32-bit)
Pentium 4 G1 (or equivalent) or later (64-bit)Pentium 4M (or equivalent) or later (32-bit)
Pentium 4 G1 (or equivalent) or later (64-bit)
RAM256 MB1 GB
Screen Resolution1024 x 768 pixels1024 x 768 pixels
Operating SystemWindows 8.1/8/7/Vista (32-bit and 64-bit)
Windows XP SP3 (32-bit)
Windows Server 2012 R2 (64-bit)
Windows Server 2008 R2 (64-bit)
Windows Server 2003 R2 (32-bit)Windows 8.1/8/7/Vista (32-bit and 64-bit)
Windows XP SP3 (32-bit)
Windows Server 2012 R2 (64-bit)
Windows Server 2008 R2 (64-bit)
Windows Server 2003 R2 (32-bit)
Disk Space620 MB5 GB (includes default drivers from the NI Device Drivers media)
Color PaletteN/ALabVIEW and the LabVIEW Help contain 16-bit color graphics. LabVIEW requires a minimum color palette setting of 16-bit color.
Temporary Files DirectoryN/ALabVIEW uses a directory for storing temporary files. National Instruments recommends that you have several megabytes of disk space available for this temporary directory.
Adobe ReaderN/AYou must have Adobe Reader installed to search PDF versions of all LabVIEW manuals.
NoteThe following list describes restrictions for using LabVIEW on Windows:
[*]LabVIEW does not support Windows 2000/NT/Me/98/95 or Windows XP x64.
[*]You cannot access LabVIEW using a Guest account on Windows.
Installation InstructionsYou can access the LabVIEW Installation Guide and the LabVIEW Upgrade Notes at ni.com as well as on the installation media.
Visit ni.com/security to view and subscribe to receive security notifications about National Instruments products. Visit ni.com/critical-updates for information about critical updates from National Instruments.
Known IssuesWhen run on Windows (64-bit), LabVIEW 2015 (64-bit) provides access to more memory than a 32-bit operating system or a 32-bit application can provide. LabVIEW 2015 (64-bit) includes nearly all of the development environment features of LabVIEW 2015 (32-bit).
LabVIEW 2015 (64-bit) supports many hardware devices. Refer to the National Instruments website for information about drivers compatible with LabVIEW 2015 (64-bit). For GPIB devices, you must use at least NI-488.2 2.6 for Windows. Refer to the specific hardware documentation for more information about compatibility with LabVIEW 2015 (64-bit).
Supported ModulesThe following list contains additional changes to LabVIEW that are not included in the LabVIEW Help, the LabVIEW Upgrade Notes, or both:
[*]National Instruments does not support remote front panels for Google Chrome starting from version 42. Visit the National Instruments website for more information.
Bug Fixes
IDFixed Issue
52263Some operations on integer waveforms lose dt value
225616Error 1172 (System.Reflection.AmbiguousMatchException) is returned when using the .NET invoke node to call a .NET method that also contains an additional generic version of the same method.
257275Format Into String does not work with the %d format for numbers larger than I32
278730Web Services ignore the No App switch on RT targets
315474Feedback node with waveform data input, and greater than 2 iterations of delay, outputs an array of waveform
333388Incorrect highlight execution order with LVOOP property node
348592Select node causes buffer copy
361311"Natural log of 1 + x" primitive incorrectly returns NaN for small positive values
372784LabVIEW 2012 and later have added overhead to dynamic dispatch calls when compared to LabVIEW 2011
377653There is inconsistent labeling on 'Constrained Nonlinear Curve Fit.vi' TRLM instance.
392232Autopreallocate Arrays and Strings VI Property Can Crash LabVIEW when not in FPGA Context
392446Installing LabVIEW on a Windows laptop decreases battery life
397550LabVIEW can switch to different Front Panels or Block Diagrams when going between LabVIEW and other programs.
400736Error -4403 returned from Write Palette.vi for Template VIs
401689Constrained Non-Linear Optimization VI has Potential for Infinite Loop
408351The Bookmark Manager window is not closed when 'Esc' key is pressed
413786Help button does not work on Setup page of LabVIEW 64-bit Example Finder
413954Slow VI compilation with complex VI
419089Infinite loop in NI_Gmath.lvib:cno_isisubopt.vi under certain conditions
421739Quick drop ctrl+r needs to wire the To More Specific/Generic side terminal instead of center terminal
424089The advanced analysis Kummer Function returns 'NaN' instead of correct values for certain combinations of input parameters.
425562Scan from String requires a space between modifiers when using SI notation
426157VI invoke node Find CtrlWithKeyFocus don't work with typedefs
434426Reading from same UDP port twice simultaneously crashes LV
435756Web Services reset all resource VIs to their default parameters (GET as Terminal/XML) when multiple files are simultaneously added to project.
437915When converting a Timestamp into a string with the Format into String primitive, certain incorrect format strings will cause the End of file encountered error.
438751Renaming a group in a Mixed Signal Graph crashes LabVIEW once there is a plot containing data
441262Call Library Function Nodes maximum error checking mode incorrectly reports memory corruption with CStrs and PStrs.
443165Modifying the dependencies of a Packed Project Library (PPL) may cause LabVIEW to crash
444759Default probes should fit to probe watch window pane
444851Encapsulated PostScript (EPS) is not supported on Mac 64-bit
447789"RecipeBkUp::SanityCheck()" Crash
449869"ICallPiccCallback" 0x89B93EF0
451059"CProjectItemWrapper::GetPropertyBag(IlvProjectPropertyBag**)"
453489Minimizing the lvlib group in VI hierarchy messes up the entire VI hierarchy.
458700Equals? Function executes slowly on long strings
458724Uninstalling myRIO Module 2013 causes LabVIEW Getting Started Screen to become unresponsive.
462624Mouse wheel scrolling does not work on the Functions Palette.
463275Using the same Application twice in installer causes unexpected behavior
463408Log scale on a Graph does not use correct minimum with certain data
463760Improved security of an authenticated session when used over an un-encrypted connection like http.
466635Add new "Create Unique File" VI to vi.lib
468062Path to URL.vi does not handle network path
468921Auto-populating folders may not update their contents correctly
469070In some cases, Fract/Exp String To Number VI does not convert the string correctly
469178Sound Examples do not have volume control
469269Error when VIPM quits LV -- svcloc_interface.cpp line 1702
471706Cannot paste into destination name of installer properties in LabVIEW 2013
474004Multiple LabVIEW windows do not group in RHEL.
474143Copy functions returns a permission error (error code 8) occasionally when running in a loop
474764A VI can hang at Occurrences if Allow Debugging is disabled
476028MAX/NIER report: Null pointer dereference in LVBroker.dll!CniLVBroker::HandleVIClose(niLVReq & req, int (void) *)
476714The INI file created for a LabVIEW-built executable contains a truncated list of VIs in the "server.vi.access=" line when enabling TCP/IP with multiple Exported VIs
477112If you cancel the file dialog, it will never show again in Write to Measurement File Express VI.
477280When using , Application Builder post-build VIs do not get passed the proper path
477352In the TDMS File Viewer VI, the menu becomes partially hidden after making the plot legend visible
477864When a number of controls are grouped on a tab control page, switching to that page takes a long time, proportional to the number of controls grouped
477954VI Analyzer throws error 1 when analyzing project with a Networked Computer under the Target Folder.
478485Selecting a Polymorphic VI while loading a caller VI causes a crash due to missing polymorphic instances
478854Source Distribution Target Directory not used, VIs placed in startup folder
478906Conditional Double Probe does not handle NaN equality check
479161Error 7 When Building Installer for EXE with Custom Destinations
480103Using VirtualBench API through TestStand and the LVRTE causes crashes on exit
480480Invoke Node shows the English shortname at the first drop in German LabVIEW
480921Unable to delete and re-add a destination folder successfully in build specification of a LabVIEW Installer
484575Issue writing to individual digital waveform channels in TDMS files
484662LabVIEW Runtime installer should allow multiple versions in one distribution
484767Bookmarks changed event does not return the path of the VI(s) in which the bookmarks changed
484940Create Express VI tool throws Error 1099 when template VIs are marked as Source Only
485412Make Ctr-W shortcut wire to inner terminals of tunnels
486475LabVIEW crashes when adding a saved copy of an lvclass member to an lvlib
488710Multicolumn Listbox Key Navigation is not consistent
489848"Remove empty cases" option in case structure disappears when Subdiagram Label is visible.
490378Report Generation Toolkit, headers.vi has a reference leak.
490606Web Service installer fails to install on Win Server 2008 R2
491093Application Web Server fails to run on VxWorks when root directory has too many files
491198Any VI that has a VI Documentation greater than 8000 characters will cause the context help window to truncate the documentation.
491539Unexpected behavior with Resample Waveforms (Single Shot).vi
496699LabVIEW crashes when attempting to reinitialize unused plots in plot legend of waveform graph
497131The WebDAV Put.vi when executed on a cRIO target can lead to a memory leak
497256CoreAnimation thread warning when calling a LabVIEW-built Framework on Mac OS X 10.0
497516Replacing a Waveform control with an Array(Silver) crashes LabVIEW with internal error in datamgr.cpp.
497755Cannot reset the values of Build Specification Version in Set Build Specification Version VI to zero
499042Incorrect Diagram Identifier reported by LV Compare tool when comparing case structures
500986Error 1 generated in property node when remote debugging
501004Performance improvements for 3D Plot VIs
501633Variable Engine does not have a "Run-Time" product for deployment.
502081Ctrl+shift+E (find in project) doesn't work for clone VIs.
502105"New..." dialog only looks for VI templates in the LabVIEW directory, which is not writable on Linux systems
503234The method "Synchronize in all Contexts" causes LabVIEW to crash.
505523Diff and Merge do not work with Enable Hyperlinks
508525Improve "Select a VI" experience with Quick Drop Replace and Insert
509097LabVIEW crashes when sending an empty input array to the Preallocated Read from File VI
509204Format Into String outputs an incorrect string when using Timestamp data and an order modifier
510063LabVIEW does not exit properly after encountering a NIER exception
510881LabVIEW Crash when saving Library containing Shared Variables with Class Object in Typedef.
510908Application Builder slows when builds involve PPLs with controls in them
511588Currently selected item in the Connector Pane selection menu is not outlined
511708LabVIEW crashes when use "save method" to save the UDF VI if the MathScript RT Module and Control Design and Simulation Module are both installed.
511770The Waveform Unbundle/Bundle node pair on InPlace Element Structures cannot be scripted
512153Cursor in LabVIEW can disappear when switching between tools.
512294Crash in search 1D array when run on VI with host interface node
512464After making a change in Format Into String, the containing VI does not recompile automatically.
512761The input XML containing "\n" hangs the LabVIEW storage VIs.
513188Improved Bookmark Manager performance by adding additional caching.
513259Substitute Actor VI does not transfer nested actors
513281Improved error handling in AB_Engine_EXE_Call_Write_Icons.vi
513457"Change to Array" menu option should not appear on tab controls or XControls.
513871MAX/NIER report: Access violation in lvrt.dll!std::_Tree
513963Classes containing NaN values compare incorrectly when using the Equals function
514518LabVIEW 2014 crashes upon close while an RFmx example VI is running continuously from a LabVIEW Project context.
515054Icon transparency of VIs is not maintained when building a Source Distribution
515086Building VIs with certain recursive dependencies can cause a LabVIEW crash
515223Advanced TDMS Write broken wire behavior is incorrect.
515763The To Long Integer conversion bullet can crash when converting a float64 array to an int32 array if the start of the input data (just after the dimsize) is not 16 bytes aligned.
515779Invoke node Append String returns error 1043 while display style set to backslash "\" codes
515884LabVIEW crashes when using the Class Browser to select a class which contains an accessor available via property nodes
515920Memory issues due to timestamp handling in the Data Storage VIs.
516057LabVIEW Application Builder API Build (path).vi returns unclear error 1055 when Build Specification name or target name is incorrect
516217The WebDAV Put.vi when executed on a cRIO target can lead to a memory leak
516227UI Thread LabVIEW code cannot execute while a Time Stamp Control's 'Set Time and Date' window is visible.
516506'Build All' error does not indicate which build specification failed.
516674LabVIEW crashes when dragging a class member VI from the Class Browser onto an Untitled VI of a Library
516841VeriStand crashes after manipulating a System Definition via the System Explorer
516905Cannot get VI Path/Name for Type Definitions, Classes, or Global VIs if dependency is missing
517128Error 1357 when building using two VIs with the same name and only capitalization differences.
517307Mass Compile of VeriStand 2014 LabVIEW examples will crash LabVIEW
519216LabVIEW crash when closing subVI Icon Editor that was opened from VI Hierarchy.
519533IDFinder downloads the wrong version of VIs for Instrument drivers
519665LV crashes when copying user event data while handling high priority user events
520343Runtime popup menus appear on the Project properties dialog
521114Property VIs of classes do not require that inputs/outputs match the class itself
521509LabVIEW security update
524370LabVIEW 2014 crashes on VI load if old error cluster controls are connected to case structures or conditional terminals
Accessing the HelpSelect Help»Find Examples from LabVIEW to launch the NI Example Finder. You can modify an example VI to fit an application, or you can copy and paste from one or more examples into a VI that you create.
Automating the Installation of NI ProductsIf the NI product you are installing uses Microsoft .NET 4.0, the .NET installer may run before any NI software installs and may require a reboot before the installation of NI software begins. To avoid a .NET reboot, install .NET 4.0 separately before you install NI software.
When you install National Instruments software on Microsoft Windows 8.x, you will notice a few additional tiles in the Apps view, including shortcuts to NI application software products such as NI LabVIEW, Measurement & Automation Explorer (NI MAX), and NI Launcher.
Using NI LauncherNoteNI MAX does not appear as a desktop shortcut when installed on Microsoft Windows 8.x. You can launch NI MAX either from the Apps view or from within NI Launcher.
Pinning Frequently Used ApplicationsIf you want to find a particular application or related files, such as documentation files, from the Start screen, you can access all installed files from the Apps view. To get to the Apps view, right-click anywhere on the Start screen and select All apps (Windows 8.0) or click the down arrow on the bottom left of the screen (Windows 8.1).
LabVIEW will drop support for Microsoft Windows Vista, Windows XP, and Windows Server 2003 as of July 1, 2016. Versions of LabVIEW that ship after July 1, 2016 will not install or run on Windows Vista, Windows XP, or Windows Server 2003. For detailed information about NI application software product life cycles, visit ni.com/info and enter one of the following Info Codes:
ProductInfo Code
LabVIEWlifecycle
LabWindows™/CVI™cvi_lifecycle
Measurement Studiomstudiolifecycle
TestStandtslcp
DIAdemddlcp
SignalExpressselcp
VeriStandnivslifecycle
Legal Information© 2004–2015 National Instruments. All rights reserved.
National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
You can find end-user license agreements (EULAs) and third-party legal notices in the following locations after installation:
[*]Notices are located in the <National Instruments> directories.
[*]EULAs are located in the <National Instruments>\Shared\MDF\Legal\license directory.
[*]Review <National Instruments>\_Legal Information.txt for information on including legal information in installers built with NI products.
If you are an agency, department, or other entity of the United States Government ("Government"), the use, duplication, reproduction, release, modification, disclosure or transfer of the technical data included in this manual is governed by the Restricted Rights provisions under Federal Acquisition Regulation 52.227-14 for civilian agencies and Defense Federal Acquisition Regulation Supplement Section 252.227-7014 and 252.227-7015 for military agencies.
Content from the IVI specifications reproduced with permission from the IVI Foundation.
Trademarks
Patents
374715C-01
页:
[1]