create_bar_code_modelT_create_bar_code_modelCreateBarCodeModelCreateBarCodeModelcreate_bar_code_model (Operator)
Name
create_bar_code_modelT_create_bar_code_modelCreateBarCodeModelCreateBarCodeModelcreate_bar_code_model
— Create a model of a bar code reader.
Signature
void CreateBarCodeModel(const HTuple& GenParamName, const HTuple& GenParamValue, HTuple* BarCodeHandle)
void HBarCode::HBarCode(const HTuple& GenParamName, const HTuple& GenParamValue)
void HBarCode::HBarCode(const HString& GenParamName, double GenParamValue)
void HBarCode::HBarCode(const char* GenParamName, double GenParamValue)
void HBarCode::HBarCode(const wchar_t* GenParamName, double GenParamValue)
(Windows only)
void HBarCode::CreateBarCodeModel(const HTuple& GenParamName, const HTuple& GenParamValue)
void HBarCode::CreateBarCodeModel(const HString& GenParamName, double GenParamValue)
void HBarCode::CreateBarCodeModel(const char* GenParamName, double GenParamValue)
void HBarCode::CreateBarCodeModel(const wchar_t* GenParamName, double GenParamValue)
(Windows only)
Description
The operator create_bar_code_modelcreate_bar_code_modelCreateBarCodeModelCreateBarCodeModelCreateBarCodeModelcreate_bar_code_model
creates a generic model for
reading all types of supported bar code symbols. The result of this operator
is a handle to the bar code model (BarCodeHandleBarCodeHandleBarCodeHandleBarCodeHandlebarCodeHandlebar_code_handle
), which is used
for all further operations on the bar code, like modifying the model,
reading a symbol, or accessing the results of the symbol search.
In general, bar codes will be found and decoded without any additional
adjustment of the parameters. Therefore, GenParamNameGenParamNameGenParamNameGenParamNamegenParamNamegen_param_name
and
GenParamValueGenParamValueGenParamValueGenParamValuegenParamValuegen_param_value
are empty tuples by default. In the case of poor
image quality or abnormal geometric characteristics of the bar code,
which requires special parameter settings for a successful decoding of
the bar code symbols, parameters can be adjusted already while creating
the bar code model. Alternatively, parameters can be changed later on as
well by applying the operator set_bar_code_paramset_bar_code_paramSetBarCodeParamSetBarCodeParamSetBarCodeParamset_bar_code_param
or
set_bar_code_param_specificset_bar_code_param_specificSetBarCodeParamSpecificSetBarCodeParamSpecificSetBarCodeParamSpecificset_bar_code_param_specific
. For a detailed
description of the available model parameters see set_bar_code_paramset_bar_code_paramSetBarCodeParamSetBarCodeParamSetBarCodeParamset_bar_code_param
.
Execution Information
- Multithreading type: reentrant (runs in parallel with non-exclusive operators).
- Multithreading scope: global (may be called from any thread).
- Processed without parallelization.
This operator returns a handle. Note that the state of an instance of this handle type may be changed by specific operators even though the handle is used as an input parameter by those operators.
Parameters
GenParamNameGenParamNameGenParamNameGenParamNamegenParamNamegen_param_name
(input_control) attribute.name(-array) →
HTupleMaybeSequence[str]HTupleHtuple (string) (string) (HString) (char*)
Names of the generic parameters that can be
adjusted for the bar code model.
Default value: []
List of values: 'barcode_height_min'"barcode_height_min""barcode_height_min""barcode_height_min""barcode_height_min""barcode_height_min", 'barcode_width_max'"barcode_width_max""barcode_width_max""barcode_width_max""barcode_width_max""barcode_width_max", 'barcode_width_min'"barcode_width_min""barcode_width_min""barcode_width_min""barcode_width_min""barcode_width_min", 'check_char'"check_char""check_char""check_char""check_char""check_char", 'composite_code'"composite_code""composite_code""composite_code""composite_code""composite_code", 'element_size_max'"element_size_max""element_size_max""element_size_max""element_size_max""element_size_max", 'element_size_min'"element_size_min""element_size_min""element_size_min""element_size_min""element_size_min", 'element_size_variable'"element_size_variable""element_size_variable""element_size_variable""element_size_variable""element_size_variable", 'meas_thresh'"meas_thresh""meas_thresh""meas_thresh""meas_thresh""meas_thresh", 'meas_thresh_abs'"meas_thresh_abs""meas_thresh_abs""meas_thresh_abs""meas_thresh_abs""meas_thresh_abs", 'min_code_length'"min_code_length""min_code_length""min_code_length""min_code_length""min_code_length", 'min_identical_scanlines'"min_identical_scanlines""min_identical_scanlines""min_identical_scanlines""min_identical_scanlines""min_identical_scanlines", 'num_scanlines'"num_scanlines""num_scanlines""num_scanlines""num_scanlines""num_scanlines", 'orientation'"orientation""orientation""orientation""orientation""orientation", 'orientation_tol'"orientation_tol""orientation_tol""orientation_tol""orientation_tol""orientation_tol", 'persistence'"persistence""persistence""persistence""persistence""persistence", 'quiet_zone'"quiet_zone""quiet_zone""quiet_zone""quiet_zone""quiet_zone", 'start_stop_tolerance'"start_stop_tolerance""start_stop_tolerance""start_stop_tolerance""start_stop_tolerance""start_stop_tolerance", 'stop_after_result_num'"stop_after_result_num""stop_after_result_num""stop_after_result_num""stop_after_result_num""stop_after_result_num", 'timeout'"timeout""timeout""timeout""timeout""timeout", 'train'"train""train""train""train""train", 'upce_encodation'"upce_encodation""upce_encodation""upce_encodation""upce_encodation""upce_encodation"
GenParamValueGenParamValueGenParamValueGenParamValuegenParamValuegen_param_value
(input_control) attribute.value(-array) →
HTupleMaybeSequence[Union[float, int, str]]HTupleHtuple (real / integer / string) (double / int / long / string) (double / Hlong / HString) (double / Hlong / char*)
Values of the generic parameters that can be
adjusted for the bar code model.
Default value: []
Suggested values: 0, 0.1, 1, 1.5, 2, 8, 32, 45, 'present'"present""present""present""present""present", 'absent'"absent""absent""absent""absent""absent", 'none'"none""none""none""none""none", 'CC-A/B'"CC-A/B""CC-A/B""CC-A/B""CC-A/B""CC-A/B", 'auto'"auto""auto""auto""auto""auto", 'high'"high""high""high""high""high", 'low'"low""low""low""low""low", 'true'"true""true""true""true""true", 'false'"false""false""false""false""false"
BarCodeHandleBarCodeHandleBarCodeHandleBarCodeHandlebarCodeHandlebar_code_handle
(output_control) barcode →
HBarCode, HTupleHHandleHTupleHtuple (handle) (IntPtr) (HHandle) (handle)
Handle for using and accessing the bar code model.
Result
The operator create_bar_code_modelcreate_bar_code_modelCreateBarCodeModelCreateBarCodeModelCreateBarCodeModelcreate_bar_code_model
returns the value TRUE if the
given parameters are correct. Otherwise, an exception will be raised.
Possible Successors
find_bar_codefind_bar_codeFindBarCodeFindBarCodeFindBarCodefind_bar_code
See also
clear_bar_code_modelclear_bar_code_modelClearBarCodeModelClearBarCodeModelClearBarCodeModelclear_bar_code_model
References
International Standard ISO/IEC 15420: “Information technology - Automatic
identification and data capture techniques -
Bar code symbology specification - EAN/UPC”;
Reference number ISO/IEC 15420:2000 (E);
ISO/IEC 2000.
International Standard ISO/IEC 16390: “Information technology - Automatic
identification and data capture techniques -
Bar code symbology specification - Interleaved 2 of 5”;
Reference number ISO/IEC 16390:1999 (E);
ISO/IEC 1999.
International Standard ISO/IEC 16388: “Information technology - Automatic
identification and data capture techniques -
Bar code symbology specification - Code 39”;
Reference number ISO/IEC 16388:1999 (E);
ISO/IEC 1999.
American National Standards Institute, Inc.(ANSI): “Uniform Symbology
Specification Code 93”;
ANSI/AIM-BC5-2000;
AIM 2000.
International Standard ISO/IEC 15417: “Information technology - Automatic
identification and data capture techniques -
Bar code symbology specification - Code 128”;
Reference number ISO/IEC 15417:2000 (E);
ISO/IEC 2000.
American National Standards Institute, Inc.(ANSI): “Uniform Symbology
Specification Codabar”;
ANSI/AIM-BC3-2000;
AIM 2000.
International Standard ISO/IEC 24724: “Information technology - Automatic
identification and data capture techniques -
Reduced Space Symbology (RSS) bar code symbology specification”;
Reference number ISO/IEC 24724:2006 (E);
ISO/IEC 2006.
International Standard ISO/IEC 24723: “Information technology - Automatic
identification and data capture techniques -
EAN.UCC Composite bar code symbology specification”;
Reference number ISO/IEC 24723:2006 (E);
ISO/IEC 2006.
Module
Bar Code