hand_eye_calibration
— Perform a hand-eye calibration.
hand_eye_calibration( : : X, Y, Z, Row, Col, NumPoints, RobotPoses, CameraParam, Method, QualityType : CameraPose, CalibrationPose, Quality)
The operator hand_eye_calibration
determines the 3D pose of a robot
(“hand”) relative to a camera (“eye”). With this information, the
results of image processing can be transformed into the coordinate system of
the robot which can then, e.g., grasp an inspected part.
Please note that the operator hand_eye_calibration
does not support
3D sensors. A hand-eye calibration including 3D sensors is only supported
by the operator calibrate_hand_eye
. That operator furthermore
provides a more user-friendly interface to the hand-eye calibration than the
operator hand_eye_calibration
, since the reference coordinate
systems are explicitly indicated.
There are two possible configurations of robot-camera (hand-eye) systems:
The camera can be mounted on the robot or be stationary and observe the
robot. Note that the term robot is used in place for a mechanism that moves
objects. Thus, you can use hand_eye_calibration
to calibrate many
different systems, from pan-tilt heads to multi-axis manipulators.
In essence, systems suitable for hand-eye calibration are described by a closed chain of four Euclidean transformations. In this chain two non-consecutive transformations are either known from the robot controller or computed from calibration points seen by a camera system. The two other constant transformations are computed by the hand-eye calibration procedure.
A hand-eye calibration is performed similarly to the calibration of the
external camera parameters (see camera_calibration
): You acquire a
set of images of a calibration object, determine correspondences between
known calibration points and their projection in the images and pass them to
hand_eye_calibration
via the parameters X
, Y
,
Z
, Row
, Col
, and NumPoints
. If
you use the standard calibration plate, the correspondences can be determined
very easily with the operators find_caltab
and
find_marks_and_pose
. Furthermore, the camera is identical for
the complete calibration sequence and is specified by the internal camera
parameters in CameraParam
. The internal camera parameters are
calibrated beforehand deploying the operator calibrate_cameras
or
camera_calibration
.
In contrast to the camera calibration, the calibration object is not moved
manually. This task is delegated to the robot, which either moves the camera
(mounted camera) or the calibration object (stationary camera). The robot's
movements are assumed to be known and therefore are also used as an input for
the calibration (parameter RobotPoses
).
The output of hand_eye_calibration
are the two poses
CameraPose
and CalibrationPose
. Their pose type is
identical to the pose type of the first input robot pose.
Basically, two hand-eye configurations can be distinguished and are discussed in more detail below, followed by general information about the process of hand-eye calibration.
In this configuration, the calibration object remains stationary and the camera is moved to different positions by the robot. The main idea behind the hand-eye calibration is that the information extracted from a calibration image, i.e., the pose of the calibration object relative to the camera (i.e., the external camera parameters), can be seen as a chain of poses or homogeneous transformation matrices, from the calibration object via the base of the robot to its tool (end-effector) and finally to the camera:
Moving camera: cam_H_cal = cam_H_tool * tool_H_base * base_H_cal
| | |
CameraPose
RobotPoses
CalibrationPose
From the set of calibration images, the operator hand_eye_calibration
determines the two transformations at the ends of the chain, i.e., the pose
of the robot tool in camera coordinates
(,CameraPose
) and
the pose of the calibration object in the robot base coordinate system
(,CalibrationPose
).
In contrast, the transformation in the middle of the chain,
, is known but changes for each
calibration image, because it describes the pose of the robot moving the
camera, or to be more exact its inverse pose (pose of the base coordinate
system in robot tool coordinates). You must specify the inverse robot poses
in the calibration images in the parameter RobotPoses
.
Note that when calibrating SCARA robots it is not possible to
determine the Z translation of CalibrationPose
. To eliminate
this ambiguity the Z translation of CalibrationPose
is internally
set to 0.0 and the CameraPose
is calculated accordingly.
It is necessary to determine the true translation in Z after
the calibration (see calibrate_hand_eye
).
In this configuration, the robot grasps the calibration object and moves it in front of the camera. Again, the information extracted from a calibration image, i.e., the pose of the calibration object in camera coordinates (the external camera parameters), are equal to a chain of poses or homogeneous transformation matrices, this time from the calibration object via the robot's tool to its base and finally to the camera:
Stationary camera: cam_H_cal = cam_H_base * base_H_tool * tool_H_cal
| | |
CameraPose
RobotPoses
CalibrationPose
Analogously to the configuration with a moving camera, the operator
hand_eye_calibration
determines the two transformations at the ends
of the chain, here the pose of the robot base coordinate system in camera
coordinates
(,CameraPose
)
and the pose of the calibration object relative to the robot tool
(,CalibrationPose
).
The transformation in the middle of the chain,
, describes the pose of the
robot moving the calibration object, i.e., the pose of the tool relative to
the base coordinate system. You must specify the robot poses in the
calibration images in the parameter RobotPoses
.
Note that when calibrating SCARA robots it is not possible to
determine the Z translation of CalibrationPose
. To eliminate
this ambiguity the Z translation of CalibrationPose
is internally
set to 0.0 and the CameraPose
is calculated accordingly.
It is necessary to determine the true translation in Z after
the calibration (see calibrate_hand_eye
).
The following sections discuss individual questions arising from the
use of hand_eye_calibration
. They are intended to be a guideline
for using the operator in an application, as well as to help
understanding the operator.
3D calibration points given in the world coordinate system (X
,
Y
, Z
) and their associated projections in the image
(Row
, Col
) form the basis of the hand-eye calibration.
In order to be able to perform a successful hand-eye calibration, you need
at least three images of the 3D calibration points that were obtained under
different poses of the manipulator. In each image at least four points must
be available, in order to compute internally the pose transferring the
calibration points from their world coordinate system into the camera
coordinate system.
In principle, you can use arbitrary known points for the calibration.
However, it is usually most convenient to use the standard calibration plate,
e.g., the one that can be generated with gen_caltab
. In this
case, you can use the operators find_caltab
and
find_marks_and_pose
to extract the position of the calibration plate
and of the calibration marks and the operator caltab_points
to read
the 3D coordinates of the calibration marks (see also the description of
camera_calibration
).
The parameter NumPoints
specifies the number of 3D calibration
points used for each pose of the manipulator, i.e., for each image.
With this, the 3D calibration points which are stored in a linearized
fashion in X
, Y
, Z
, and their corresponding
projections (Row
, Col
) can be associated with the
corresponding pose of the manipulator (RobotPoses
). Note that
in contrast to the operator camera_calibration
the 3D coordinates
of the calibration points must be specified for each calibration image,
not only once, and thus can vary for each image of the sequence.
The following conditions, especially if using a standard calibration plate, should be considered:
The position of the calibration marks (moving camera: relative to the robot's base; stationary camera: relative to the robot's tool) and the position of the camera (moving camera: relative to the robot's tool; stationary camera: relative to the robot's base) must not be changed between the images.
The internal camera parameters (CameraParam
) must be
constant and must be determined in a previous camera calibration step
(see camera_calibration
). Note that changes of the image size,
the focal length, the aperture, or the focus cause a change of the
internal camera parameters.
The theoretical lower limit of the number of image to acquire is three. Nevertheless, it is recommended to have 10 or more images at hand, in which the position of the camera or the robot hand are sufficiently different.
For articulated (i.e., non-SCARA) robots the amount of rotation between the images is essential and should be at least 30 degrees or better 60 degrees. The rotations between the images must exhibit at least two different axes of rotation. Very different orientations lead to precise calibration results. For SCARA robots there is only one axis of rotation. The amount of rotation between the images should also be large.
In each image, the calibration plate must be completely visible (including its border).
Reflections or other disturbances should not impair the detection of the calibration plate and its calibration marks.
If individual calibration marks instead of the standard calibration plate are used at least four marks must be present in each image.
In each image, the calibration plate should at least fill one quarter of the entire image for a precise computation of the calibration to camera transformation, which is performed internally during hand-eye calibration.
As mentioned, the camera must not be modified between the acquisition of the individual images. Please make sure that the focus is sufficient for the expected changes of the camera to calibration plate distance. Therefore, bright lighting conditions for the calibration plate are important, because then you can use smaller apertures, which result in a larger depth of focus.
In the parameter RobotPoses
you must pass the poses of the robot in
the calibration images (moving camera: pose of the robot base in robot tool
coordinates; stationary camera: pose of the robot tool in robot base
coordinates) in a linearized fashion. We recommend to create the robot poses
in a separate program and save in files using write_pose
. In the
calibration program you can then read and accumulate them in a tuple as shown
in the example program below. In addition, we recommend to save the pose of
the robot tool in robot base coordinates independent of the hand-eye
configuration. When using a moving camera, you then invert the read poses
before accumulating them. This is also shown in the example program.
Via the Cartesian interface of the robot, you can typically obtain the pose
of the tool in base coordinates in a notation that corresponds to the pose
representations with the codes 0 or 2 (OrderOfRotation
=
'gba' or 'abg' , see create_pose
). In this case, you
can directly use the pose values obtained from the robot as input for
create_pose
.
If the Cartesian interface of your robot describes the orientation in a
different way, e.g., with the representation ZYZ (), you can create the
corresponding homogeneous transformation matrix step by step using the
operators hom_mat3d_rotate
and hom_mat3d_translate
and then
convert the matrix into a pose using hom_mat3d_to_pose
. The following
example code creates a pose from the ZYZ representation described above:
Please note that the hand-eye calibration only works if the robot poses
RobotPoses
are specified with high accuracy!
The length of the tuple NumPoints
corresponds to the number of
different positions of the manipulator and thus to the number of calibration
images. The parameter NumPoints
determines the number of
calibration points used in the individual positions. If the standard
calibration plate is used, this means 49 points per position (image).
If, for example, 15 images were acquired, NumPoints
is a tuple
of length 15, where all elements of the tuple have the value 49.
The number of images in the sequence, which is determined by the length of
NumPoints
, must also be taken into account for the tuples of
the 3D calibration points and the extracted 2D marks, respectively. Hence,
for 15 calibration images with 49 calibration points each, the tuples
X
, Y
, Z
, Row
, and Col
must
contain values each. These tuples
are ordered according to the image the respective points lie in, i.e.,
the first 49 values correspond to the 49 calibration points in the first
image. The order of the 3D calibration points and the extracted 2D
calibration points must be the same in each image.
The length of the tuple RobotPoses
also depends on the number of
calibration images. If, for example, 15 images and therefore 15 poses
are used, the length of the tuple RobotPoses
is
(15 times 7 pose parameters).
The first seven parameters thus determine the pose of the manipulator
in the first image, and so on.
The parameter Method
determines the type of algorithm used for the
hand-eye calibration: With 'linear' a linear algorithm is chosen,
which is fast but in many practical situations not accurate enough.
'nonlinear' selects a non-linear algorithm, which results in
the most accurately calibrated poses and which is the method of choice.
For the calibration of SCARA robots the parameter Method
must
be set to 'scara_linear' or 'scara_nonlinear' ,
respectively. While the arm of an articulated robot has three rotary
joints typically covering 6 degrees of freedom (3 translations and 3
rotations), SCARA robots have two parallel rotary joints and one parallel
prismatic joint covering only 4 degrees of freedom (3 translations and 1
rotation). Loosely speaking, an articulated robot is able to tilt its
end effector while a SCARA robot is not.
The parameter QualityType
switches between different possibilities
for assessing the quality of the calibration result returned in
Quality
. 'error_pose' stands for the pose error of the
complete chain of transformations. To be more precise, a tuple with four
elements is returned, where the first element is the root-mean-square error
of the translational part, the second element is the root-mean-square error
of the rotational part, the third element is the maximum translational
error and the fourth element is the maximum rotational error.
With 'standard_deviation' , a tuple with 12 elements containing the
standard deviations of the two poses is returned: The first six elements
refer to the camera pose and the others to the pose of the calibration
points. With 'covariance' , the full 12x12 covariance matrix of
both poses is returned. Like poses, the standard deviations and the
covariances are specified in the units [m] and [°].
Note that selecting 'linear' or 'scara_linear' for
the parameter Method
enables only the output of the pose error
('error_pose' ).
X
(input_control) number-array →
(real / integer)
Linear list containing all the x coordinates of the calibration points (in the order of the images).
Y
(input_control) number-array →
(real / integer)
Linear list containing all the y coordinates of the calibration points (in the order of the images).
Z
(input_control) number-array →
(real / integer)
Linear list containing all the z coordinates of the calibration points (in the order of the images).
Row
(input_control) number-array →
(real / integer)
Linear list containing all row coordinates of the calibration points (in the order of the images).
Col
(input_control) number-array →
(real / integer)
Linear list containing all the column coordinates of the calibration points (in the order of the images).
NumPoints
(input_control) integer-array →
(integer)
Number of the calibration points for each image.
RobotPoses
(input_control) pose-array →
(real / integer)
Known 3D pose of the robot for each image (moving camera: robot base in robot tool coordinates; stationary camera: robot tool in robot base coordinates).
CameraParam
(input_control) campar →
(real / integer / string)
Internal camera parameters.
Method
(input_control) string →
(string)
Method of hand-eye calibration.
Default value: 'nonlinear'
List of values: 'linear' , 'nonlinear' , 'scara_linear' , 'scara_nonlinear'
QualityType
(input_control) string(-array) →
(string)
Type of quality assessment.
Default value: 'error_pose'
List of values: 'covariance' , 'error_pose' , 'standard_deviation'
CameraPose
(output_control) pose →
(real / integer)
Computed relative camera pose: 3D pose of the robot tool (moving camera) or robot base (stationary camera), respectively, in camera coordinates.
CalibrationPose
(output_control) pose →
(real / integer)
Computed 3D pose of the calibration points in robot base coordinates (moving camera) or in robot tool coordinates (stationary camera), respectively.
Quality
(output_control) real(-array) →
(real)
Quality assessment of the result.
* Note that, in order to use this code snippet, you must provide * the camera parameters, the calibration plate description file, * the calibration images, and the robot poses. read_cam_par('campar.dat', CameraParam) CalDescr := 'caltab.descr' caltab_points(CalDescr, X, Y, Z) * Process all calibration images. for i := 0 to NumImages-1 by 1 read_image(Image, 'calib_'+i$'02d') * Find marks on the calibration plate in every image. find_caltab(Image, CalPlate, CalDescr, 3, 150, 5) find_marks_and_pose(Image, CalPlate, CalDescr, CameraParam, 128, 10, 18, \ 0.9, 15, 100, RCoordTmp, CCoordTmp, StartPose) * Accumulate 2D and 3D coordinates of the marks. RCoord := [RCoord, RCoordTmp] CCoord := [CCoord, CCoordTmp] XCoord := [XCoord, X] YCoord := [YCoord, Y] ZCoord := [ZCoord, Z] NumMarker := [NumMarker, |RCoordTmp|] * Read pose of the robot tool in robot base coordinates. read_pose('robpose_'+i$'02d'+'.dat', RobPose) * Moving camera? Invert pose. if (IsMovingCameraConfig == 'true') pose_to_hom_mat3d(RobPose, base_H_tool) hom_mat3d_invert(base_H_tool, tool_H_base) hom_mat3d_to_pose(tool_H_base, RobPose) endif * Accumulate robot poses. RobotPoses := [RobotPoses, RobPose] endfor * * Perform hand-eye calibration. * hand_eye_calibration(XCoord, YCoord, ZCoord, RCoord, CCoord, NumMarker, \ RobotPoses, CameraParam, 'nonlinear', 'error_pose', \ CameraPose, CalibrationPose, Error)
The operator hand_eye_calibration
returns the value 2 (H_MSG_TRUE)
if the given parameters are correct. Otherwise, an exception will be raised.
find_marks_and_pose
,
camera_calibration
,
calibrate_cameras
write_pose
,
convert_pose_type
,
pose_to_hom_mat3d
,
disp_caltab
,
sim_caltab
find_caltab
,
find_marks_and_pose
,
disp_caltab
,
sim_caltab
,
write_cam_par
,
read_cam_par
,
create_pose
,
convert_pose_type
,
write_pose
,
read_pose
,
pose_to_hom_mat3d
,
hom_mat3d_to_pose
,
caltab_points
,
gen_caltab
,
calibrate_hand_eye
K. Daniilidis: “Hand-Eye Calibration Using Dual Quaternions”;
International Journal of Robotics Research, Vol. 18, No. 3,
pp. 286-298; 1999.
M. Ulrich, C. Steger: “Hand-Eye Calibration of SCARA Robots Using Dual
Quaternions”; Pattern Recognition and Image Analysis, Vol. 26, No. 1,
pp. 231-239; January 2016.
Calibration