set_metrology_model_paramT_set_metrology_model_paramSetMetrologyModelParamSetMetrologyModelParamset_metrology_model_param (Operator)
Name
set_metrology_model_paramT_set_metrology_model_paramSetMetrologyModelParamSetMetrologyModelParamset_metrology_model_param
— Set parameters that are valid for the entire metrology model.
Signature
Description
set_metrology_model_paramset_metrology_model_paramSetMetrologyModelParamSetMetrologyModelParamSetMetrologyModelParamset_metrology_model_param
sets or changes parameters that are
valid for the entire metrology model MetrologyHandleMetrologyHandleMetrologyHandleMetrologyHandlemetrologyHandlemetrology_handle
.
For an explanation of the concept of 2D metrology see the
introduction of chapter 2D Metrology.
The following values for GenParamNameGenParamNameGenParamNameGenParamNamegenParamNamegen_param_name
and GenParamValueGenParamValueGenParamValueGenParamValuegenParamValuegen_param_value
are possible:
Calibration
If both internal camera parameters and the 3D pose of the measurement plane
are set, apply_metrology_modelapply_metrology_modelApplyMetrologyModelApplyMetrologyModelApplyMetrologyModelapply_metrology_model
calculates the results
in metric coordinates.
- 'camera_param'"camera_param""camera_param""camera_param""camera_param""camera_param":
-
Often the internal camera parameters are the result of calibrating
the camera with the operator calibrate_camerascalibrate_camerasCalibrateCamerasCalibrateCamerasCalibrateCamerascalibrate_cameras
(see Calibration for the sequence of the parameters
and the underlying camera model). It is possible to discard the internal
camera parameters by setting 'camera_param'"camera_param""camera_param""camera_param""camera_param""camera_param" to [].
Default value: []
- 'plane_pose'"plane_pose""plane_pose""plane_pose""plane_pose""plane_pose":
-
The 3D pose of the measurement plane
in camera coordinates. It is possible to discard the pose by
setting 'plane_pose'"plane_pose""plane_pose""plane_pose""plane_pose""plane_pose" to [].
Default value: []
Definition of a new reference system
When adding the metrology objects to the metrology model using e.g.,
add_metrology_object_genericadd_metrology_object_genericAddMetrologyObjectGenericAddMetrologyObjectGenericAddMetrologyObjectGenericadd_metrology_object_generic
,
add_metrology_object_circle_measureadd_metrology_object_circle_measureAddMetrologyObjectCircleMeasureAddMetrologyObjectCircleMeasureAddMetrologyObjectCircleMeasureadd_metrology_object_circle_measure
etc. the positions and
orientations are given with respect to the image coordinate system which
has its origin in the upper left corner of the image.
In some cases it may be necessary to change the reference system with respect
to which the metrology objects are given. This is for instance the case
when using a shape model to align the metrology model in a new image.
The results from find_generic_shape_modelfind_generic_shape_modelFindGenericShapeModelFindGenericShapeModelFindGenericShapeModelfind_generic_shape_model
can only be directly used in
align_metrology_modelalign_metrology_modelAlignMetrologyModelAlignMetrologyModelAlignMetrologyModelalign_metrology_model
if the reference system of the metrology model
is the same as the system in which the shape model is given (see
align_metrology_modelalign_metrology_modelAlignMetrologyModelAlignMetrologyModelAlignMetrologyModelalign_metrology_model
for more details).
- 'reference_system'"reference_system""reference_system""reference_system""reference_system""reference_system":
-
The tuple given in
GenParamValueGenParamValueGenParamValueGenParamValuegenParamValuegen_param_value
should contain
[row, column, angle]. By default the reference system is the image
coordinate system which has its origin in the top left corner.
A new reference system is defined with respect to the image coordinate
system by its translation (row,colum) and its rotation angle (angle).
All components of the metrology model are converted into the new
reference coordinate system.
In the following figure, the reference system of the metrology model is
set to the center of the image.
set_metrology_model_param(MetrologyHandle, 'reference_system', [Height/2,Width/2,0])set_metrology_model_param(MetrologyHandle, "reference_system", [Height/2,Width/2,0])SetMetrologyModelParam(MetrologyHandle, "reference_system", [Height/2,Width/2,0])SetMetrologyModelParam(MetrologyHandle, "reference_system", [Height/2,Width/2,0])SetMetrologyModelParam(MetrologyHandle, "reference_system", [Height/2,Width/2,0])set_metrology_model_param(MetrologyHandle, "reference_system", [Height/2,Width/2,0])
|
Default value: [0, 0, 0]
Scaling the results
The results of the measurement queried by
get_metrology_object_resultget_metrology_object_resultGetMetrologyObjectResultGetMetrologyObjectResultGetMetrologyObjectResultget_metrology_object_result
can be scaled by setting a scaling
factor.
- 'scale'"scale""scale""scale""scale""scale":
-
The parameter 'scale'"scale""scale""scale""scale""scale" must be specified as the ratio of the
desired unit to the original unit.
If no camera parameters are given, the default unit is pixel.
If 'camera_param'"camera_param""camera_param""camera_param""camera_param""camera_param" and 'plane_pose'"plane_pose""plane_pose""plane_pose""plane_pose""plane_pose" are set, the original
unit is determined by the coordinates of the calibration object.
Standard HALCON calibration plates are defined in metric coordinates. If it
was used for the calibration, the desired unit can be set directly.
The relation of units to scaling factors is given in the following table:
Unit |
Scaling factor |
m |
1 |
dm |
10 |
cm |
100 |
mm |
1000 |
um, microns |
1e6
|
List of values: 1.0, 0.1, 'm'"m""m""m""m""m",
'cm'"cm""cm""cm""cm""cm", 'mm'"mm""mm""mm""mm""mm", 'microns'"microns""microns""microns""microns""microns",
'um'"um""um""um""um""um"
Default value: 1.0
Execution Information
- Multithreading type: reentrant (runs in parallel with non-exclusive operators).
- Multithreading scope: global (may be called from any thread).
- Processed without parallelization.
This operator modifies the state of the following input parameter:
During execution of this operator, access to the value of this parameter must be synchronized if it is used across multiple threads.
Parameters
MetrologyHandleMetrologyHandleMetrologyHandleMetrologyHandlemetrologyHandlemetrology_handle
(input_control, state is modified) metrology_model →
HMetrologyModel, HTupleHHandleHTupleHtuple (handle) (IntPtr) (HHandle) (handle)
Handle of the metrology model.
GenParamNameGenParamNameGenParamNameGenParamNamegenParamNamegen_param_name
(input_control) attribute.name →
HTuplestrHTupleHtuple (string) (string) (HString) (char*)
Name of the generic parameter.
Default:
'camera_param'
"camera_param"
"camera_param"
"camera_param"
"camera_param"
"camera_param"
List of values:
'camera_param'"camera_param""camera_param""camera_param""camera_param""camera_param", 'plane_pose'"plane_pose""plane_pose""plane_pose""plane_pose""plane_pose", 'reference_system'"reference_system""reference_system""reference_system""reference_system""reference_system", 'scale'"scale""scale""scale""scale""scale"
GenParamValueGenParamValueGenParamValueGenParamValuegenParamValuegen_param_value
(input_control) attribute.value(-array) →
HTupleMaybeSequence[Union[str, float, int]]HTupleHtuple (string / real / integer) (string / double / int / long) (HString / double / Hlong) (char* / double / Hlong)
Value of the generic parameter.
Default:
[]
Suggested values:
1.0, 0.1, 'm'"m""m""m""m""m", 'cm'"cm""cm""cm""cm""cm", 'mm'"mm""mm""mm""mm""mm", 'microns'"microns""microns""microns""microns""microns", 'um'"um""um""um""um""um"
Result
If the parameters are valid, the operator
set_metrology_model_paramset_metrology_model_paramSetMetrologyModelParamSetMetrologyModelParamSetMetrologyModelParamset_metrology_model_param
returns the value 2 (
H_MSG_TRUE)
. If
necessary, an exception is raised.
Possible Predecessors
create_metrology_modelcreate_metrology_modelCreateMetrologyModelCreateMetrologyModelCreateMetrologyModelcreate_metrology_model
,
set_metrology_model_image_sizeset_metrology_model_image_sizeSetMetrologyModelImageSizeSetMetrologyModelImageSizeSetMetrologyModelImageSizeset_metrology_model_image_size
Possible Successors
add_metrology_object_genericadd_metrology_object_genericAddMetrologyObjectGenericAddMetrologyObjectGenericAddMetrologyObjectGenericadd_metrology_object_generic
,
get_metrology_object_model_contourget_metrology_object_model_contourGetMetrologyObjectModelContourGetMetrologyObjectModelContourGetMetrologyObjectModelContourget_metrology_object_model_contour
See also
set_metrology_object_paramset_metrology_object_paramSetMetrologyObjectParamSetMetrologyObjectParamSetMetrologyObjectParamset_metrology_object_param
,
align_metrology_modelalign_metrology_modelAlignMetrologyModelAlignMetrologyModelAlignMetrologyModelalign_metrology_model
,
get_metrology_model_paramget_metrology_model_paramGetMetrologyModelParamGetMetrologyModelParamGetMetrologyModelParamget_metrology_model_param
Module
2D Metrology