Operators |
open_io_device — Open and configure an I/O device.
open_io_device( : : IOInterfaceName, IODeviceName, GenParamName, GenParamValue : IODeviceHandle)
The operator open_io_device opens and configures the chosen I/O device interface for the specific device. The device interface is specified by the base name of the underlying library and passed to IOInterfaceName. The interface library will be loaded dynamically when configuring the first specific device for this device interface. The specific device itself is addressed by a name passed to IODeviceName. Available names can be queried by query_io_interface. The device can be configured by the parameters GenParamName and GenParamValue. A reference to the device instance is returned in IODeviceHandle. If the instance of the device is not needed any more, it should be released and closed via the operator close_io_device.
Having opened a specific device, a transmission channel can be opened by calling open_io_channel. Values on the I/O channel can be read and written by the operators read_io_channel and write_io_channel on an opened transmission channel, afterwards.
An opened device instance can be reconfigured by using the operators set_io_device_param and get_io_device_param.
Please check the directory 'doc/html/reference/io' for documentation about your specific I/O device interface, where all supported device specific parameters are listed.
On Windows Systems, error dialog boxes from the operating system can occur when dependency modules of the interface are not found, e.g., the according SDK was not installed. The occurrence of the error boxes can be controlled by setting Windows' Error Mode. Please refer to the description of SetErrorMode within the Windows MSDN documentation.
This operator returns a handle. Note that the state of an instance of this handle type may be changed by specific operators even though the handle is used as an input parameter by those operators.
HALCON I/O interface name.
Default value: []
Suggested values: 'ADLINK-DAQPilot' , 'ADLINK-EOS' , 'Advantech' , 'Contec' , 'Interface' , 'NIDAQmx' , 'OPC_Classic' , 'OPC_UA'
Dynamic parameter values.
Default value: []
Handle of the opened I/O device.
* Select a suitable i/o device interface of name IOInterfaceName query_io_interface (IOInterfaceName, 'io_device_name', DeviceNames) open_io_device (IOInterfaceName, DeviceNames[0], [], [], IODeviceHandle) query_io_device (IODeviceHandle, [], 'io_channel_names.digital_input', ChannelInputNames) open_io_channel (IODeviceHandle, ChannelInputNames[0], [], [], IOChannelHandle) read_io_channel (IOChannelHandle, Value, Status)
If the parameters are valid, the operator open_io_device returns the value 2 (H_MSG_TRUE). If necessary an exception is raised. In this case, an extended error information may be set and can be queried with the operator get_extended_error_info.
set_io_device_param, get_io_device_param, open_io_channel
Foundation